' .'' ' ` �� �i A(� <br /> �i � � <br /> Warehouse is fully conditioned. No envelope changes made to the "building within the building" <br /> and no changes made to the plans. <br /> b. The U-value requirements for the interior windows and doors on the office/mezzanine <br /> should also be shown to be in compli,�nce with a non-conditioned space on the exterior. � <br /> Please indicate the U values of all fenestrati�n to meet energy code requirements, to include man <br /> and rolling doors, per WSEC C402.1.4 and C402.4. <br /> Warehouse is fully conditioned. No envelope changes made to the "building within the building" <br /> and no changes made to the plans. <br /> 4. Where a change in space conditioning is triggering new work, compliance with the building <br /> thermal envelope requirements should be shown in section and summarized on the drawings, per <br /> WSEC section C503.1. Please indicate the method of building envelope compliance by completing a <br /> total UA alternative worksheet, or providE� a completed prescriptive worksheet to include <br /> detailed R-Values of new exterior walls, roaf-ceiling details, slab on grade and foundation details, <br /> per WSEC section C402.1. <br /> No change in space conditioning category. W,arehouse will remain fully conditioned. No changes <br /> made to the plans. <br /> MECHANICAL <br /> 1. Deferred plan review will still require neec.net mechanical summary compliance forms, and <br /> equipment catalog cuts. <br /> Mechanical WSEC compliance forms included in the plans. See sheets M2.0 and M2.1.The following <br /> cut sheets are provided: Make-up Air units MUA-x, Unit Heaters UH-x, High Volume Low Speed Fans <br /> HVLS-x, Exhaust Fans EF-1,2. <br /> 2. The mechanical requirements for outside air should be shown on the drawings for the combined <br /> warehouse and vehicular occupancy. This may also impact the outside air requirements for the office. <br /> Ventilation calculation included in the mechanical plans.See sheet M0.1. <br />