' � • • � • • � � � <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Minimum Req uireme�its This fable summarizes prescriptive compliance requirements for opaque e/ements and fenestration.Reler <br /> for Prescriptive Compliance to Tab/es C402.1.3,C402.1.4 and C402.4 in the 2015 WSEC for important footnotes that apply to <br /> these tab/es. Re%r to Section C402 for all applicable requirements that app/y lor each envelope element <br /> type and app/icable exceptions. Refer to Section C4 f 0 for a/l applicab/e information for refrigerated <br /> spaces. <br /> Table C402.1.3 Nores 1,7 Table C402.1.4 nO�es 1,2 <br /> Prescriptive Path Insulation Minimum R-Value Assembly Maximum U-factor <br /> Occu ancv Grou All Other Grou R All Other Grou R <br /> Opaque Elements <br /> Roof.c <br /> Insulation Entircl ahove Deck R-3R c.i. R-3R c.i. U-0.027 U-0.027 <br /> Metal Buildin�(wi�h thermal s acer block) <br /> �0��; R_25+R-I 1 Ls R-25+R-I I LS U-0.031 U-0.031 <br /> Attic and Othcr R-49 R-49 U-0.021 U-0.021 <br /> Joisi or single ralicr R-49 R-49 U-0.027 U-0.027 <br /> 1Vallc,AGove-grnde <br /> M<tss c - Nutc 6 R_�i.3 c.i. Nuic[, U-0.078 <br /> R-)�c.i. U-0.104 <br /> Mass transfer deck�lab edge No R-Value for preticriptive compliance U-0.200 U-0200 <br /> Metal Buildim� R-19 c.i. R-19 c.i. U-0.053 U-0.052 <br /> Stecl Framed R-13+k-IOc.i. R-19+R-8.5�,i. U-QO55 U-0.055 <br /> Wood Framed and Other R-21 w/int.frame R-?1 w/int.irame U-0.054 U-0.054 <br /> Below Grade Wall �"�`� Same as above grade Same as above grade <br /> Floors <br /> Mass R-30 c.i. R-30 c.i. U-0.031 U-0.03] <br /> Stecl Joist R-3R+R-10 c.i. R-38+R-10 c.i. U-0.029 U-0.029 <br /> Wood Framed and Other R-30 R-30 U-0.029 U-0.029 <br /> Slab-On-Grade Floors <br /> Unheated R-10 for 24 in.(from top of slab) F-0.54 F-0.�4 <br /> Heated Noce 5 R-]0 perimeter&under entire slab F-0.55 F-0.55 <br /> Opnque Doors <br /> Swin�ing No R-Value for prescriptive compliance U-0.37 U-0.37 <br /> Nonswinvin (Roll-u or slidin�) R-4.75 R-4J5 U-0.34 U-034 <br /> Table C402.4-0-30%of waU arca,or <br /> 30%-40%per Section C402.3.1./DLZ Section C402.3J.3 High Performance <br /> or Sectio�i C402.3J.4 DOAS Fenestratian Oprion-0-40%of wall area <br /> Fenestration Assembl Maximum U-factor No�e`�,z <br /> Vertic•a!Fenestrntion <br /> Nonmctal framin�� U-(1.30 U-0.30 U-0?8 U-0?S <br /> Mctal�'ramin�(fixcd) U-0.3R U-0.38 U-0.34 U-0.34 <br /> Mctal I'r.unin (o�crahle) U-0.40 U-0.40 U-036 U-0.36 <br /> Entr:mcc doors U-0.60 U-0.60 U-0.60 U-0.60 <br /> Skylights <br /> Sk lights U-(1.50 U-0.50 U-0.50 U-0.50 <br /> Fenestration Assembly Maximum SHGC Factor <br /> Vertica(!'enestra(io�r PF<0?:north-SHGC=0.53; PF<0.2:north-SHGC=0.46; <br /> all other SHGC=0.4 all othcr SHGC=03S <br /> 0.2<_PF<0.5:north-SHGC-O.SR; 0.2<_PF<0.5:north-SHGC-0.51; <br /> all other-SHGG0.48 all other-SHGG0.42 <br /> PF>_0.5:a11 orientations-SHGC-0.64 PF>_0.5:all oricntations-SHGC-OS6 <br /> Sk di lrts SHGG0.35 SHGC-035 <br /> C410.2 Refrigerated Spaces Insvlation Insulation Minimum R-Value Assembly Maximum U-factor <br /> Freezers-{Vnik-in m:d{Vnrelrouse <br /> Roof/Ceiling R-32 U-0.030 <br /> Wall R-32 U-0.030 <br /> Door R-32 U-0.030 <br /> Door-trans arent rcach-in triple-panc.heat-reticctive treated or gas <br /> Floor R-28 U-0.035 <br /> Coolers-iValk-in arrd Warelrousc <br /> Roof/Cciling R-25 U-0.039 <br /> Wall R-35 U-0.039 <br /> Door R-25 U-0.039 <br /> Door-tran,eparent rcach-in double-��ane,heat-rcl�lective trealcd& <br /> gas filL or comply with freezer door req. <br /> Floor No Rec uircment �! <br /> 9',1� '�' � <br />