Laserfiche WebLink
, 2004 Washington State Nonresidential Energy Code Compliance Form <br /> . • • • ' . • • ' <br /> 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 <br /> ProjectAddress Mountain View Business Centre Building A Date 5�11�2017 <br /> Space Heat Type 0 Electric resistance �All other For Building Department Use <br /> Glazin s exterior wall area 8•-;$ Prop. 45.0� Max.Target <br /> � �t t asonry Option O Yes �O r�o <br /> Fo Notes If glazing area exceeds maximum allowed in Table,then calculate adjusted areas on back(over). <br /> Building Component Proposed UA Target UA <br /> List components by assembly ID&page# U-factor x Area(A) =UA(U x A) U-factor x Area(A) =UA(U x A) <br /> U= Plan ICA3.1 6 A9.1 0.550 1871.0 1029.1 0.550 1871.0 1029.i <br /> U= Plan ID: Glazing% Electric Resist. Other Heating <br /> � o, U= Plan ID: 0-30% 0.40 0.55 <br /> r � U= Plan ID: >30-45% see note above 0.45 <br /> >C7 U= Plan ID: <br /> U= Plan ID: <br /> U= Plan ID: <br /> � U= Plan ICA2.3 0.700 <br /> m Q U= Plan ID: Glazing% Electric Resist. Other Heating <br /> � m U= Plan ID: 0-30% 0.6 0.7 <br /> � � U= Plan ID: >30-45% see note above 0.6 <br /> � <br /> `° v, U= Plan ICA2.3 0.700 1184.0 828.8 <br /> � <br /> � � U= Plan ID: <br /> O � U= Plan ID: <br /> � U= PIanID: 0.700 1184.0 828.8 <br /> � ` U= Plan ICA3.1 0.600 2573.0 1543.8 0.600 2573.0 1543.8 <br /> �o U= Plan ID: Electric Resist. Other Heating <br /> O� U= Plan ID: 0.60 0.60 <br /> N ` R= Plan ID: 0.036 <br /> �o R= Plan ID: Electric Resist. Other Heating <br /> R= Plan ID: 0.031 0.036 <br /> R= Plan ICA2.3 0.046 85106.0 3914.9 0.046 85106.0 3914.9 <br /> a�= <br /> o � R= Plan ID: Electric Resist. Other Heating <br /> R= Plan ID: 0.034 0.046 <br /> R= Plan ICA4-1 0.109 32348.0 3525.9 0.109 32348.0 3525.9 <br /> R= Plan ID: ** <br /> �' R= Plan ID: ** <br /> m <br /> � R= Plan ID: Electric Resist. Other Heating <br /> � R= Plan ID: Frame-Wd 0.062 0.062 <br /> � <br /> a R= Plan ID: Frame-Mtl 0.062 0.109 <br /> � R= Plan ID: ass Wall+i 0.15 0.15 <br /> "Note:sum of Target Areas here should equal Target Opaque Wall Area(see back) ++see mass wall Criteria <br /> R= Plan ID: <br /> o � R= Plan ID: Electric Resist. Other Heating <br /> m � R= Plan ID: Int Ins 0.062 0.062 <br /> Note: if insulated to levels required for opaque walls, list above with opaque walls Ext Ins 0.07 0.07 <br /> �, R= Plan ID: 0.056 <br /> � Electric Resist. Other Heating <br /> � o R= Plan ID: <br /> � <br /> o c R= Plan ID: 0.029 0.056 <br /> o � <br /> � R= Plan ID: <br /> R= Plan ICAl.l 0.!i40 1314.0 709.6 0.540 1314.0 709.6 <br /> o� R= Plan ID: Electric Resist. Other Heating <br /> �m <br /> m m R= Plan ID: F=0.54 F=0.54 <br /> � <br /> R= Plan ID: (see Table 13-1 for radiant floor values) <br /> 'For CMU walls, indicate core insulation material. Totals 124396.0 11552.0 Totals 124396.0 11552.0 <br /> To comply: 1)Proposed Total UA shall not exceed Target Total UA. <br /> 2)Proposed Total Area shall equal Target Total Area. <br /> � � � ��� � <br /> � <br />