. ' 2004 Washington State Nonresidential Energy Code Compliance Form <br /> ' • • . . • <br /> 2004 Washington State Nonresidenlial Energy Code Compliance Forms Revised May 2005 <br /> Project Info ProjectAddress Moun View Business Centre suilding A Date 5/11/2017 <br /> iate Boulevard and shuksan way For 8uilding Department Use <br /> �� Everett, Washington <br /> RG� Applicant Name synchesi5 ac <br /> �p G ApplicantAddress: llyll xE i5t Street, su�te io3 <br /> Applicant Phone: 4zs-6n6-ieie <br /> Project Description � New Building ❑ Addition ❑ Alteration ❑Change of Use <br /> 0✓ Prescriptive � Component Performance ❑ Systems Analysis <br /> Compliance Option (See Decision Flowchart(over)for qualifications) <br /> Space Heat Type � Electric resistance 0 All other (see over for definitions) <br /> Total Glazing Area Electronic version: these values are automatically taken from ENV-UA-1. <br /> Glazing Area Calculation (rough opening) Gross Exterior <br /> Note: Below grade walls may be included in the �vertical&overhd) divided by Wall Area times 100 equals °/a Glazing <br /> Gross Exterior Wall Area if they are insulated to <br /> the level required for opaque walls. 3 O S�J . O — 3 G 7 92 . O X �00 = 8 . 3% <br /> � yes Check here if using this option and if project ineets all require�nents for the Concrete/Masonry <br /> Concrete/Masonry Option Option. See Decision Flowchart(over�for qualifications. Enter requirements for each yualifying <br /> Oflo assembly belo�n�. <br /> Envelope Requirements(enter values as applicable) Opaque Concrete/Masonry Wall Requirements <br /> Fully heated/cooled space Wall Maximum U-factor is 0.15(R5.7 continuous ins) <br /> Minimum Insulation R-values CMU block walls with insulated cores comply <br /> Roofs Over Attic If project qualifies for Concrete/Masonry Option,list walls <br /> with HC>_9.0 Btu/ft�•°F below(other walls must meet <br /> All Other Roofs R-21 Opaque Wall requirements). Use descriptions and values <br /> Opaque Walls' R-19 from Table 10-9 in the Code. <br /> Below Grade Walls Wall Description U-factor <br /> Floors Over Unconditioned Space (including insulation R-value&position) <br /> Slabs-on-Grade R-10 <br /> Radiant Floors <br /> Maximum U-factors <br /> Opaque Doors 0.600 <br /> Vertical Glazing 0.550 <br /> Overhead Glazing 0.700 <br /> Maximum SHGC(or SC) <br /> Vertical/Overhead Glazing 0.450 <br /> Semi-heated space 2 <br /> Minimum Insulation R-values <br /> Roofs Over Semi-Heated SpacesZ R-11 <br /> 1.Assemblies with metal framing must comply with overall U-factors <br /> 2. Refer to Section 1310 for qualifications and requirements <br /> Notes: <br /> Entire building is semi-heated. Values for conditioned spaces are for future tenant <br /> improvements. <br /> � <br /> � � � � �� <br /> �,� <br />