+ • . <br /> Ted Budden <br /> To: Kevin Fagerstrom <br /> Cc: Tony Lee <br /> Subject: FW: 3231 Broadway Mixed-Use Building W permit status <br /> Kevi n, <br /> Please find attached an analysis of the Code deficiencies and associated violations that exist within the building and <br /> group of occupancies located at 3231 Broadway Ave. <br /> I have worked with Meg Haley,Tony Lee and representatives of the Everett Fire Department to assess the conditions <br /> present here and to evaluate the extent and nature of the code violations. <br /> It is our determination that this building is Unsafe as defined by IPMC section 108.1.1.This structure is being operated <br /> and occupied contrary to law, IPMC sections 106.1 and 108.4 <br /> The owner has made some efforts to resolve the code concerns over the last several months as mentioned in the <br /> summary attached. These efforts unfortunately have fallen significantly short ofthe immediate need. <br /> It is our position that the code violations present within this building be abated immediately. Failure to address the <br /> violations in a timely manner should cause condemnation to occur of the affected areas of the building. Please initiate <br /> enforcement action as your schedule allows. <br /> If you need additional information or have questions regarding our position, please contact Tony Lee or myself. <br /> Regards <br /> Ted Budden <br /> From: Meg Haley <br /> Sent: Monday, December 08, 2014 11:29 AM <br /> To: Ted Budden <br /> Cc: Paul McKee; Tony Lee; Rick Robinson; Jim Venturo; Eric Hicks; Kevin Fagerstrom; Steve Ingalsbe <br /> Subject: 3231 Broadway Mixed-Use Building W permit status <br /> RE: Referral to Code Enforcement for further action for 3231 Broadway <br /> Ted, <br /> From a single manufacturer with support and retail facilities in the 1970's,the building is now a mixed-use multi-tenant <br /> building. Based on review of the BW1410-052 10/30/14 permit plans, the building does not provide minimum <br /> safeguards to protect or warn occupants in the event of f�re, per the 2012 International Property Maintenance Code <br /> fIPMC), Section 108.1.1 Unsafe Structures. <br /> � <br /> Egress Fhvtas.pd# <br /> 1. IPMC 702.1 'Means of Egress' requirements are not met for the second floor residences (6000 square feet). <br /> a. The fire escape is in disrepair and does not provide direct access to grade. <br /> b. A posted sign indicates the fire escape is a second exit, but it does not have an illuminated exit sign or <br /> emergency lighting. <br /> c. The second required exit through the first floor does not have an illuminated exit sign or emergency lighting. <br /> � 1:_--^' <br /> � <br />