• • <br /> Structural <br /> 1. The roof structure covering and supporting the hot tub has deteriorated, and may not <br /> be adequate to support the imposed dead and live loads, per IPMC section 304.4. <br /> a. Please submit framing plans and calculations for the hot tub and enclosure, if the <br /> hot tub is to remain; or, <br /> b. Please indicate demolition of the hot tub. <br /> Occupancy <br /> 1. The occupant load calculations and occupancy types should be identified in the code <br /> analysis and shown on the plans. <br /> a. NOTE: The proposed occupancy (use) types and locations in the building shown <br /> on the BW1410-004 permit plans to determine required egress are subject to <br /> review, non-conforming use determination, and additional requirements from <br /> Planning, Fire, Public Works, and Traffic, in addition to the Building Division. <br /> b. At any time, a building permit is required for a change of occupancy to assembly <br /> use, which will trigger a seismic analysis of the building and other requirements, <br /> per IBC section 3408.1, other chapters of the building code, and other <br /> departments. <br /> c. Please indicate �he demising walls cn the basement level, io mee� egress and <br /> �rl+�r��E�i��g aa;��9�e s e�p_ai��emFM�i�- <br /> d. The occupancy types and occupai�c load calculaiions for all floors ar�d rooi�ns ofi <br /> the building should be shown on the plans, per IBC Chapter 3 and IBC Table <br /> 1004.1.2. <br /> Construction <br /> 1. The penthouse structure and spa is not designed for the resistance of moisture <br /> penetration to the structure, and should be shown on the drawings as removed or <br /> repaired, per IPMC 108.1.5 (5.) <br /> 2. The required plumbing fixture count in the basement and on the first floor should be <br /> shown to meet the current requirements, based on occupancy, per IBC Chapter 29. <br /> Accessibility <br /> 1. Accessibility has been required since the 1982 UBC. <br /> 2. New doors or reinstalled doors should be shown on the drawings with hardware that is <br /> operable without tight grasping, pinching or twisting of the wrist, per IBC section <br /> 1008.1.9.1. <br /> Energy <br /> 1. New exterior doors or enclosures should be shown to be fully compliant with the <br /> requirements of the energy code. <br /> Page 2 of 3 <br />