� • � <br /> c. Locking devices on egress doors should be shown on the drawings to comply <br /> with IBC section 1008.1.9.3. <br /> d. Only the main exterior door in the basement is allowed to have the locking <br /> device, per IBC section 1008.1.9.3 (2). This would not include the loading dock <br /> exit doors. <br /> e. Access to the public way should be shown on the drawings from the loading <br /> dock, which is enclosed by a fence. <br /> 5. At least one emergency escape and rescue opening should be shown on the <br /> drawings for each sleeping room in the building, with a minimum net clear opening <br /> of 5.7 square feet, with a minimum net clear width of 20 inches, and a minimum net <br /> clear height of 24 inches, with the sill no higher than 44 inches from the floor, per <br /> UBC section 1204, 1982 and the 1991 editions, each in force at the time of the <br /> permits for the conversion of office to residential occupancies. The dimension from <br /> the bottom of the clear opening to the floor should be shown in an interior elevation. <br /> Construction <br /> 1. Plans should indicate installation of smoke alarms per IFC section 907.2.11 for each <br /> sleeping room in the building. <br /> % °�?�r.s sh���!�! :ndic�t� inst�I!zti�� �` �,rb�,� mor�;;i�� �!��ms ��e� ���' re�t^cr: 9n8 7 a� <br /> � , <br /> a�nended �y che S�a�e oi Washinc,ion, <br /> a. lJnpermitted �`uel-burning appfiances either must be shown as removed, or a <br /> separate fuel-gas permit and inspections should be obtained. <br /> 3. The wall section for construction of the stair enclosure leading to the exit discharge from <br /> the first floor should be shown on the drawings. <br /> a. The new corridor wall construction should be one hour rated, per IBC table <br /> 1018.1, since the first floor is not sprinklered. <br /> b. Storage under the stair should be shown on the drawings with one hour fire <br /> resistant rated construction, including wall, riser ceiling, and door accessing the <br /> storage area, per IBC section 1009.9.3 and table 716.5. <br /> 4. The door from the office into the corridor egress for the residence should be shown on <br /> the drawings as twenty minute rated, per IBC section 1018.1 and IBC table 716.5. <br /> 5. New or reinstalled doors should be shown on the drawings with sizes, hardware, and <br /> rating (door schedule suggested). <br /> Accessi bil ity <br /> 1. New doors or reinstalled doors should be shown on the drawings with hardware that is <br /> operable without tight grasping, pinching or twisting of the wrist, per IBC section <br /> 1008.1.9.1. <br /> Page 3 of 4 <br />