My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3231 BROADWAY 2018-01-11
>
Address Records
>
BROADWAY
>
3231
>
3231 BROADWAY 2018-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2018 2:35:26 PM
Creation date
1/11/2018 2:34:56 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3231
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • <br /> Meg Hafey <br /> From: Rick Robinson <br /> Sent: Friday, January 09, 2015 10:00 AM <br /> To: Meg Haley; Jim Venturo <br /> Cc: Tony Lee; Steve Goforth <br /> Subject: RE: Comments on fire escape permit drawings submitted for 3231 Broadway <br /> Meg and Jim, <br /> I am fine with the final ladder from the lowest platform to the alley surface being a vertical ladder as that is what was <br /> removed, and is now to be replaced. It must reach the alley surface...RR <br /> -----Original Message----- <br /> From: Meg Haley <br /> Sent: Thursday,January 08, 2015 17:01 <br /> To: Rick Robinson;Jim Venturo <br /> Subject; Comments on fire escape permit drawings submitted for 3231 Broadway <br /> Hi Jim and Rick, <br /> Attached are the drawings we received, for your review. Please see if you would like to add to or modify these <br /> additional comments which I will update on the letter I sent yesterday for an incomplete submittal. Thanks! <br /> In addition to comments on the third corrections letter referenced above, please provide the resulting details to verify <br /> that the fire escape meets the 100 psf load required for an exit, per retroactive requirements of the IFC section <br /> 1104.16.5. <br /> 1, The drawings and calculations should indicate the exit live load requirements referenced above. <br /> 2. The load served by the fire escape is 15 ((5887 square feet/200 occupants)/2 exits), per IBC Table 1004.1.2. The <br /> exception shown on the drawings for a fire escape ladder is not an acceptable termination, per IFC section 1104.16.6. <br /> 3. The drawings should indicate new construction for the fire escape structural frame, guards, handrails and the <br /> exit ladder. <br /> a. Typically this is communicated with heavier line weights. <br /> Meg <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.