My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11519 2ND AVE SE 2018-01-16
>
Address Records
>
2ND AVE SE
>
11519
>
11519 2ND AVE SE 2018-01-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2018 8:50:42 AM
Creation date
1/16/2018 8:50:32 AM
Metadata
Fields
Template:
Address Document
Street Name
2ND AVE SE
Street Number
11519
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> r,,,,-��������Z FIELD RE�OR5 <br /> ���� <br /> � - � <br /> � Pro�ect Name: Everett River Front-Simpson . ........ ... _. _ �._...Repol't: 035 � <br /> _ <br /> . <br /> � GeoDes�gn# P01 on 127 03 Daie 05/03 <br /> y9. _____. _.. _... __. ___ <br /> _._______.._.._.__._.�.......�.__.___�. _.---_-.- _. __.._.._� <br /> _ ._._ . _.___._._ _._ <br /> � Permit: <br /> � Reports with Unresolved Nonconformance Issues: � ` <br /> � � PW1505-005 � <br /> 3 °j <br /> i ` <br /> � . . . . . . -�. � �� . . � <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) , WediFl2f Clear, 50�S <br /> � �_ _ _ --- -163 _.._._ _...._ <br /> , _...._ --- -- --- ___ <br /> __ � <br /> � Ron Bowen(Polygon) Eddy Stevens(Polygon) AC�IVdI/DepdPtUre 0/1700 <br /> _ _ <br /> ; Distribution: <br /> � Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> . <br /> _......._. _. <br /> Paui McKee(City of Everett) , Dave Foster(City of Everett) Pfepdfed By: 9 <br /> � Ben Wein er <br /> a_ _ _ � . `� _ <br /> _ __. <br /> � m Site Plan(s) _� Density Test Summary r Signature:_ �-jn--=� ^_. <br /> _.� _._ <br /> � Attachments: - -� ! <br /> _.._____----..._.__ , <br /> � ❑ Installation Records m Other ; Reviewed By: <br /> �. <br /> SUMMARY of OBSERVATIONS (CONTINUED): <br /> Lot 236: <br /> Previously, GeoDesign noted that DDS over-excavated sections of Lot 236 down to material which had been compacted to <br /> greater than 95% of its maximum dry density as determined by a Modified Proctor analysis.Today, GeoDesign noted that <br /> DDS had backfilled the over-excavated areas with a 2-inch clean crushed railroad ballast material which had been <br /> compacted using the bucket of an excavator. <br /> It is the opinion of GeoDesign that the foundation subgrade area observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any su�cially loose and saturated material be removed from the base of <br /> the footing areas prior to the placement of concrete. <br /> Lot 238: <br /> Upon arrival, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 238. <br /> GeoDesign noted that the exposed foundation subgrade consisted of a gray to gray-brown silty SAND (f-m)with gravel (f-c) <br /> and a brown SILT with sand. Penetration depths along the north side were generally less than 2 inches using a 1/2 inch <br /> diameter soil probe. Penetration depths along the west, south, and east sides ranged from 6 inches to 18 inches. <br /> GeoDesign recommended that the areas be over-excavated down to firm and unyielding material and brought back to <br /> grade with structural fill. <br /> Craig with DDS stated that the over-excavated areas would be over-excavated and backfilled with a crushed rock or <br /> recycled concrete material later this week. <br /> The client and contractor were notified of our observations prior to our departure from the site. <br /> A summary of our observations and density tests can be found in the attached Figure 1, Nuclear Density Gauge Data, and <br /> Photo Log. <br /> This report presencs opinions formed az a result of our observauon of activities relating to georechnical engineering or emironmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not indude supervision or direction of ffie conVaRor,the contraaor's employees <br /> or agents. Our firm is not responsible for site safery.This field repat is a DRAFT representation of our field observations,testing,and preliminary remmmendauons. The report can only be considered <br /> final upon review of tfie GeoDesign projea mana9er,az indicated by initials in the"Reviewed 6�/'section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 / <br /> � �S <br /> ��___ <br />
The URL can be used to link to this page
Your browser does not support the video tag.