My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4006 HIGH ST 2018-01-18
>
Address Records
>
HIGH ST
>
4006
>
4006 HIGH ST 2018-01-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2018 9:50:10 AM
Creation date
1/18/2018 9:49:59 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGH ST
Street Number
4006
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � <br /> for deck joists, stairs, guardrail (on stairs and at flat deck), handrails, ledger attachment, <br /> lateral connections per R507 IRC etc. <br /> 5. Provide Washington State Energy Code (WSEC) compliance information including U- <br /> value of all windows and doors, insulation value in all components (ceiling, walls, floor, <br /> below grade walls). Show insulation required in all new (walls added w/o permits) and <br /> existing exterior walls. <br /> 6. Specify which option from table R406.2 of the Washington State Energy Code <br /> you are using to obtain the required 0.5 credits for energy code compliance. To <br /> qualify for energy credit the option chosen and the specific requirements of <br /> that option need to be shown on the construction drawings. <br /> 7. Define thermal envelope in basement. Show which portion(s) of basement are heated. If <br /> thc basement has tf�e capacity to be heated it is required to be insulated to the minimum <br /> requirements of the WSEC, provide R-21 insulation in interior walls that separate heated <br /> space from unheated spaces. If basement, or a portion of, is unheated, the floor above <br /> the unheated spaces is required to be insulated. Show on plans and provide section <br /> drawing. <br /> 8. Water heater is required to be strapped for seismic loads and installed on non- <br /> compressible insulation. Show the requirements on the plans. Provide pressure relief valve <br /> to exterior. Show on plans. <br /> 9. Provide handrails for all stairs, interior and exterior. Show requirements on the plans. <br /> Show handrails in plan views. R311.7.8 IRC <br /> 10. Specify which whole house ventilation system will be used to meet the requirements of <br /> section M1507.3. Specify the code requirements of the section chosen , do not simply <br /> reference the section. <br /> 11. Provide 36" landing (measured in the direction of travel) at the top and bottom of all stairs <br /> (interior and e�erior). <br /> 12. Specify fixture clearances of all bathroom fixtures on plan view. <br /> 13. Specify tempered safety glass in required locations as defined by section R308 IRC. Show <br /> on plans. <br /> 14. Specify how furred walls in basement will be fireblocked. <br /> 15. The windows shown on the floor plans do not accurately reflect the location of the <br /> windows in the existing structure (including basement door and window). Please correct. <br /> 16. Label all spaces for the intended use. <br /> i i�'-� i <br /> S:\1Common\Clerical\JHeilman\C1507 008 revised 11-ll-20]5(4006 High St).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.