Laserfiche WebLink
details for deck joists, stairs, guardrail (on stairs and at flat deck), handrails, ledger <br /> attachment, lateral conneckions per R507 IRC etc. <br /> �,�y7 5. Provide Washington State Energy Code (WSEC) compliance information including <br /> 5���'� � U-value of all windows and doors, insulation value in all components (ceiling, walls, <br /> � W� I��,�"` �� floor, below grade walls). Show insulation required in all new (walls added w/o permits) <br /> L�.������LS and existing exterior walls. <br /> 6. Specify which option from table R406.2 of the Washington State Energy Code you are <br /> ��j' t,, 5 using to obtain the required 0.5 credits for energy code compliance. To qualify for � <br /> � energy credit the option chosen and the specific requirements of that option need to be <br /> shown on the construction drawings. <br /> 7. befine thermal envelope in basement. Show which portion(s) of basement are heated. <br /> i���,�. � If the basement has the capacity to be heated it is required to be insulated to the <br /> minimum requirements of the WSEC, provide R-21 insulation in interior walls that <br /> separate heated space from unheated spaces. If basement, or a portion of, is unheated, <br /> the floor above the unheated spaces is required to be insulated. Show on plans and <br /> provide section drawing. <br /> n 8. Water heater is required to be strapped for seismic loads and installed on non- <br /> V''�� t'' � compressible insulation. Show the requirements on the plans. Provide pressure relief <br /> valve to exterior. Show on plans. <br /> � <br /> ! 9. Provide handrails for all stairs, interior and exterior. Show requirements on the plans. <br /> w,�� Show handrails in plan views. R311.7.8 IRC <br /> 10. Specify which whole house ventilation system will be used to meet the requirements of <br /> j%�� 3 section M1507.3. Specify the code requirements of the section chosen , do not simply <br /> � ,� <br /> reference the section. <br /> 11. Provide 36" landing (measured in the direction of travel) at the top and bottom of all <br /> ��j� 3� stairs (interior and exterior). <br /> � 12. Specify fixture clearances of all bathroom fixtures on plan view. <br /> �W��3 � <br /> ,� <br /> 13. Specify tempered safety glass in required locations as defined by section R308 IRC. <br /> Show on plans. <br /> G � � 14, Specify how furred walls in basement will be fireblocked. <br /> �y , <br /> 15.The windows shown on the floor plans do not accurately reflect the location of the <br /> ,/���'�- �� windows in the existing structure (including basement door and window). Please correct. <br /> �9� 3� 16. Label all spaces for the intended use. <br /> � � � � <br /> S:\1Common\Clerical\JHeiiman\CI507-008(4006 High St).doc <br />