• <br /> PLIBLIAVOIFIET <br /> February 7, 2017 <br /> PIERCE DESIGN <br /> e-mail: wes@wespierce.com <br /> Project: TI FOR NEW COFFEE SHOP <br /> Owner and Tenant: BLUESTEAL LLC and NARRATIVE COFFEE <br /> Job Address: 2927 WETMORE AVE <br /> Permit: B1612-030 <br /> RE: CORRECTIONS FOR BUILDING PLAN REVIEW <br /> Dear Wes, <br /> The plans submitted for permit have been examined and you are advised that revisions may be <br /> necessary before a permit can be issued. Please review and respond to the comments below. <br /> Plan review will resume when the requested information is submitted. All required submittals <br /> must be of sufficient detail and information to ensure that the proposed structures will be <br /> constructed in compliance with all adopted codes, with two sets of drawings submitted for <br /> revisions. <br /> All revisions require the person delivering the drawings to replace revisions into the two review <br /> sets here at our offices. For significant revisions, please provide two full replacement sets. If <br /> the revisions are coming directly from the blue-printer, please make arrangements with them to <br /> print two replacement sets. <br /> General <br /> 1. The reference to the WSEC C101.4.3 on the cover sheet appears to be from the 2012, <br /> not the 2015 adopted code. This code reference should be updated to correspond to <br /> current code requirements. <br /> 2. New doors should be identified on the floor plan key, and also shown per the key on the <br /> plans. <br /> 3. Please target the interior elevations on the plans for reference. <br /> Occupancy and Fire Safety <br /> 1. A change in occupancy from business to A-2 (as indicated on the cover sheet) will <br /> trigger compliance with the Everett Municipal Code 16.76.060 for suppression, which will <br /> also trigger automatic detection. <br /> 2. Please show the following on the rear exit door, door 2: <br /> a. A discernible path of egress should be shown with illuminated exit signs on the <br /> drawings, per IBC section 1011.1. <br /> b. Emergency lighting should be shown on the drawings, per IBC section 1006.1, at <br /> the interior and exterior side of the door. <br /> 3. If the intent is to change the occupancy shown on the drawings to a B occupancy per <br /> IBC section 303.1.1, then a posted occupancy sign with a maximum 49 persons should <br /> be shown on the drawings and posted in a visible location near the front door, per IBC <br /> section 1004.3. <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br /> website: www.everettwa.gov/permit January 24, 2017 email: everetteps(aeverettwa.gov / 3 <br />