Laserfiche WebLink
♦. • • <br /> Ltr. B. Burks <br /> Noyebex 13, 2006 <br /> r'-Page 2 , <br /> 7. Show how crawl space is ventilated and provide 6 mil. black vapor barrier. Lap edges <br /> / 12". <br /> 8. Provide plans and details for the covered porch. Show all components. <br /> 9. Footings to rest on undisturbed soil not. less than 18" below the finished grade. <br /> Concrete supporting wood shall extend minimum 6" above the finished grade. Show on <br /> plans. <br /> 10.Show how the new foundation is attached to the existing structure. <br /> 11.Provide product specifications for polyicosyanurate insulation. The documents <br /> submitted are for wall panel systems and foam core panels, which are specific <br /> proprietary products. The only information I was able to find showed an R-value of R- <br /> 5/inch. <br /> Please prepare a response letter showing where each item in this correction letter is addressed <br /> on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, #16........... <br /> Jeff He' man <br /> Development Technician <br /> DEDI/PLNCKMSTR/HEILMAN/C0611-002(2407-B PINE ST) <br />