•RE ALARM COMMUNICATOIP <br /> NFPA72 (2013ed) 26.6.3.3.2 COMPLIANCE (CON'T): <br /> 26.6.3.3.2.4 —Transmission Channels: <br /> 26.6.3.3.2.4(f) <br /> 26.6.3.3.2.4(f)—GSS Satisfaction(Con't): The requirements of 26.6.3.3.2.4(f) additionally are met via <br /> pre-testing of RAT's are the future protected premises by GSS technicians to determine suitable <br /> locations of RAT and its respective antenna. GSS technicians before and after installation,as well as <br /> acceptance testing shall verify compliance by communicating with central station and obtaining the <br /> proper information. It should be noted that proprietary information is utilized to demonstrate <br /> compliance. Proprietary information is acceptable per manufacturers UL compliance. <br /> 26.6.3.3.2.5—System Categories: <br /> Two-way radio alarm systems shall be divided into two categories on the basis of the following number <br /> of RASSRs present in the system. (1)A Type 6 System shall have one RASSR and at least two RARSRs. (2)A <br /> Type 7 system shall have more than one RASSR and at least two RARSRs. (3)In a type 7 system, when <br /> more than one RARASR is out of service and, as a result, any RATs are no longer being supervised, the <br /> affected supervising station shall be notified. (4)In a Type 6 system, when any RARSR is out of service, a <br /> trouble signal shall be annunciated at the supervising station. <br /> 26.6.3.3.2.5—GSS Satisfaction:Guardian Security network is a Type 7 system.As such,the compliance <br /> of line item (3) notification is automatic, as part of the proprietary software of the manufacturer. <br /> Furthermore, procedures are initiated to troubleshoot and rectify any unexpected outages. <br /> 26.6.3.3.2.6—Loading Capacities: <br /> 26.6.3.3.2.6(a) <br /> Allowable loading capacities shall be in accordance with Table 26.6.3.3.2.6(a) <br /> 26.6.3.3.2.6(a)—GSS Satisfaction:Compliance shall be checked prior to installation.As with other <br /> reporting formats(IE DACR Hunt Groups),Guardian Security Systems maintains own compliance.At <br /> request of AHJ, Guardian Security Systems can provide documentation of compliance. <br /> /C2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.