Laserfiche WebLink
InspectionType Date Result Remarks <br /> 1931 ROCKEFELLER AVE <br /> Permit: E9909-125 Status: MICROFILMED Issued: 9/28/99 Finaled:6/9/00 To Records: 6/28/05 <br /> Description: REPLACE WIRING- FIRE DAMAGE <br /> Notes/Conditions: <br /> ElecRoughln 2/22/00 Corr Reqd See notes <br /> 1-Size wire to breaker to list device <br /> 2-30 amp on dryer <br /> 3- Nail plate as discussed <br /> 4-ground metal boxes <br /> 5-2-20 amp circuits for dit and dinning <br /> 6-4 prong receptical for dryer <br /> 7-Add outside receptical to ouside front and back <br /> ElecRoughln 2/29/00 Approval See Notes <br /> OK ROUGH-IN COMPLETE-OK SERVICE- NOTE: INSTALL KNOCK OUT SEALS SMOKE <br /> DETECTOR ON 15 AMP BREAKERS <br /> Service 2/29/00 Approval <br /> Final Elec 5/23/00 Corr Reqd See notes <br /> 1-No rough in inspection of lower area,wiring in walls. <br /> 2-Secure wires, cover J boxes. <br /> 3- Main floor bath GFI/switch miswired. <br /> 4-Kitchen GFCI miswired. <br /> 5-GFCI protect all kitchen counter plugs. <br /> 6- Fridge receptacle miswired. <br /> 7-GFI receptacle in bath off kitchen (by switch). <br /> 8- Install all covers, knock out seal at HW. <br /> 9- Label panel, staple wires, GFCI plubs in lower area, remove sheetrock as discussed. <br /> Final Elec 6/9/00 Approval Reinspect, see notes <br /> Ok final-fire damage repair <br /> Final Elec 6/7/00 Corr Reqd See notes <br /> 1- baement GFCI is bad, wont trip. <br /> 2-Blank cover 4-square box. <br /> 3-Replace faulty GFCI above hot water. <br /> 4-Label panel. <br /> 5-Laundry room fan not working. <br /> 6-Kitchen GFCI miswired, doesnt remove power when tripped. <br /> 7-GFCI needed on bath plug (under switches). <br /> 8-Use hot leg for switch in samll bath fan. <br /> S:\MMcleod\Crystal\InspectionRecords1001 Hewitt.rpt 8/13/2014 Page 3 of 7 <br />