Laserfiche WebLink
Exterior Lighting Summary LTG-EXT <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Info Project Address: PSKC Everett Remodel Date 5/20/2016 <br /> 1005 Pacific Avenue For Building Department Use <br /> Everett,WA <br /> Applicant Name: AWA Electrical Consultants,Inc. <br /> Applicant Addr: 19015 36th Ave West,Suite E,Lynnwood WA <br /> Applicant Phone: (425)775-1799 <br /> Project Description 0 New Building 0 Addition la Alteration 0 Plans Included <br /> Lighting Zone <br /> As specified by jurisdiction. Zone 0 Zone 1 0 Zone 2 40 Zone 3 0 Zone 4 <br /> selection required to enable LTG-EXT <br /> rutty, <br /> Compliance Option 0 Lighting Power Density Calculations 0 Total Building Performance <br /> Building Grounds 0 Efficacy>60 lumens/W 0 Controlled by motion sensor <br /> Applies to luminaires> 100 Watts <br /> 0 Exemption (list) <br /> Exterior Lighting Alterations 0 No changes are being made to the existing exterior lighting <br /> New wiring installed to serve added fixtures and/or fixtures relocated to new circuit <br /> Provide applicable exterior lighting controls per C405.2.4 and commissioning per <br /> Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 750 <br /> Huowea vvatts Area(ft`),perimeter Huowea vvatts <br /> Tradable Surfaces Surface Description per ft2 or per If (If)or#of items x ft2(or x If) <br /> Main Entry Door 30W/LF door 6 180 <br /> width <br /> Other Entry Door 20W/LF door 3 60 <br /> width <br /> • <br /> Entry Canopies 0.4 W/ft2 Unlit <br /> Total Allowed Tradable Watts 240 <br /> Tradable Proposed Lighting Wattage (Use mfgr listed maximum input wattage for luminaire.) <br /> Number of Watts/ Watts <br /> Tradable Surface Fixture Description Fixtures Fixture Proposed <br /> Main Entry Door F7 - LED 1500 lumens 5 19 95 <br /> Other Entry Door F10 - LED 3000 lumens 2 39 78 <br /> Entry Canopies <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts' 173 <br /> watts plus the base site allowance. Any base site allowance not needed to _ <br /> make tradable watts comply can be applied to individual non-tradable <br /> Non-Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 750 <br /> Allowed Watts Area(ft2),perimeter Allowed Watts <br /> Non-Tradable Surfaces Surface Description per ft2 or per If (If)or#of items x ft2(or x If) <br /> Bldg. Façade (by perim) BLDG SOFFIT LTG 3.75 W/lf 7680 28800 <br /> Non-Tradable Proposed Lighting Wattage <br /> Number of Watts/ Watts <br /> Non-Tradable Surface Fixture Description Fixtures Fixture Proposed <br /> Bldg. Façade (by perim) F10 - LED 3000 lumens 22 39 858 <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Total excess Non-Tradable watts: 0 <br /> surface unless the total excess watts for all non-tradable surfaces are less than <br /> the remaining site allovence. Site Allowance Balance: 750 <br /> Exterior Lighting COMPLIES WITH SITE ALLOWANCE r' <br />