Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stones and all R1 Revised Jan 2014 <br /> Project Address PSKC Everett Remodel Date 5/20/2016 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and transformer requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS(Section C405.2) <br /> C405.2.1.1 Manual interior Indicate on plans the manual control type&locations served; <br /> Yes C405.2.1.2 lighting controls Indicate of plans the 50%lighting load reduction method <br /> provided or identify exception taken <br /> Indicate lighting system automatic shut-off capability-identify <br /> lighting zone areas served on plans; <br /> Automatic time Indicate locations of override switches on plans and the areas <br /> Yes C405.2.2.1 switch controls and served,include area sq.ft.; <br /> override switching <br /> Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor,daylight controls,etc) <br /> Yea C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors <br /> Daylight zones- Indicate vertical fenestration primary and secondary daylight <br /> Yes C405.2.2.3 Vertical fenestration zone areas on plans,include sq.ft.; <br /> and skylights Indicate skylight daylight zone areas on plans,include sq.ft. <br /> Daylight zone Indicate on plans the locations served by daylight zone controls; <br /> Yes C405.2.2.3.2 controls Indicate in plans the lighting load reduction(dimming)method- <br /> stepped or continuous dimming <br /> Specific application Indicate on plans the locations served by specific application <br /> NA C405.2.3 lighting controls- lighting controls <br /> General <br /> Indicate lighting control method for display and accent lighting, <br /> C405.2.3- Display and accent and display case lighting; <br /> NA Indicate these fixtures are controlled independently from both <br /> Items 1&2 lighting <br /> general area lighting and other lighting applications within the <br /> same space <br /> C405.2.3- Hotel/motel guest Provide a lighting control device at each guest room entry for all <br /> NA permanently installed fixtures in guest room; <br /> Item 3 rooms <br /> Indicated whether lighting control is manual or automatic <br /> Yes C405.2.3- Supplemental task Provide automatic shut-off vacancy controls for supplemental <br /> Item 4 lighting task lighting,including under-shelf or under-cabinet lighting <br /> Identify eligible non-visual applications and method of lighting <br /> C405.2.3- Lighting for non- control; <br /> NA Indicate these fixtures are controlled independently from both <br /> Item 5 visual applications <br /> general area lighting and other lighting applications within the <br /> same space <br /> Indicate lighting control method for lighting equipment for sale <br /> C405.2.3- Lighting equipment or demonstration; <br /> NA for sale or Indicate these fixtures are controlled independently from both <br /> Item 6 demonstration general area lighting and other lighting applications within the <br /> same space <br /> If egress lighting power density is greater than 0.05W/ft2, <br /> C405.2.3- Means of egress indicate method of automatic shut-off during unoccupied <br /> Yes Item 7 lighting periods; <br /> Identify on plans the egress fixtures that function as both normal <br /> and emergency means of egress illumination <br /> C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 <br /> NA C405.11 lighting minutes of unoccupancy for cooler and freezer lighting fixtures <br /> with lamp efficacy less than 40 lumens per watt <br /> Yes C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control <br /> controls method and locations served <br /> Exterior building Provide motion sensor controls for building grounds fixtures <br /> Yes C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 <br /> controls lumens,or identify exception taken <br /> Identify applicable commissioning documentation requirements <br /> per Section C408 or eligibility for exception; <br /> Yes C408.3 Lighting system Provide written procedures for functional testing of all automatic <br /> functional testing controls and describe the expected system response; <br /> Identify in construction documents the party responsible for <br /> functional testing of automatic lighting controls <br /> INTERIOR LIGHTING POWER & EFFICACY(Sections C405.5, C405.10, C405.11) <br /> Provide fixture schedule with fixture types,lamps,ballasts,and <br /> �<< rated watts per fixture; <br />