c. Please modify the note indicating no new work on the upper floor, since new <br /> work is shown (note 1). <br /> ✓d. Please indicate new headers (material, size, location) on the structural framing <br /> plans for new openings (note 16). <br /> Structural <br /> / 1. Please provide structural framing plans to indicate how the upper residential units are <br /> supported on bearing walls, in addition to identifying shear walls. The new moment <br /> frame should be shown on the structural drawings as well as the architectural plans. <br /> j 2. Framing plans and structural calculations should include the new toilet room and the <br /> new deck on the upper floor. The new deck has a higher live load, and the new toilet <br /> room has a higher dead load and live load. <br /> j 3. Please include live and snow loads on the drawings for reference. <br /> Egress <br /> ,/1. Emergency escape and rescue openings should be shown on drawings for all new <br /> bedrooms or new glazing shown on the plans since the 1994 permit application. A <br /> window schedule should indicate the minimum 5.7 square feet net opening, with a <br /> minimum net clear width of 20 inches, and a minimum net clear height of 24 inches, per <br /> IBC sections 1029.1 and 1029.2. <br /> a. Emergency escape and rescue clear opening should be shown on the drawings to <br /> be no higher than 44 inches from the floor, per IBC section 1029.3. <br /> Occupancy <br /> 1. The east garage should indicate the access, separation and occupancy type for the <br /> interior location of the cell tower, constructed under permit B0210-035. The garage <br /> should be shown on the drawings to meet minimum parking requirements. <br /> J 2. Occupancy separations on the code analysis should indicate if this is a non-separated or <br /> separated occupancy building, per IBC sections 508.2.4 and 508.3 <br /> Construction <br /> 1. Please submit floor plans indicating details of the required fire separations of the new <br /> bearing walls on the lower floor that support existing residential units on the second <br /> floor. <br /> a. New bearing walls (including walls built without permit approval) on the lower <br /> floor supporting second floor residential units should be shown with one hour <br /> rated construction on the drawings, per IBC section 707.5.1. <br /> b. New partitions should be detailed in section on the drawings, and located on the <br /> plans with targets to details. Where floor-ceiling assemblies are or have been <br /> modified, those modifications should also be shown on the drawings. <br /> i. Where ratings are required, the specific tested assembly number should <br /> be identified on the wall details. <br /> ii. The rated assembly construction details should also be shown on the <br /> drawings. <br /> (Page 2/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.