Search
2301 COLBY AVE 2018-03-12
>
Address Records
>
COLBY AVE
>
2301
>
2301 COLBY AVE 2018-03-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2018 2:22:08 PM
Creation date
3/12/2018 2:21:56 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2301
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V <br /> vijc <br /> b�''y �'� ,b)( �� �r. J'•'� Vim'" - � �/ 'J? <br /> ci1 <br /> N' -- <br /> � . A detail to infill the window opening on the lower floor with a rated assembly <br /> should be shown on the drawings, per IBC Table 602 and IBC Table 705.8 at <br /> property line setbacks. <br /> i. No openings are allowed on the south side of the building on the lower <br /> floor plan, due to the proximity of the property line, per IBC Table 705.8. <br /> d. There is a reference to a fire wall (note 12). Please indicate the location o the <br /> fire wall on the plans, or if this is a fire partition, per IBC sections 706 and 707. <br /> (.. The second floor plans should show new work from what was submitted on the 1994 <br /> permit application. Plan review will resume when the drawings have been corrected. <br /> Hard-wired interconnected smoke and carbon monoxide detectors should be shown on <br /> the drawings at new bedrooms, per IBC sections 907.2.11.2 and 908.7, as amended by <br /> the State of Washington. The new bedrooms can be determined by comparison to the <br /> 1994 permit plans. <br /> A! A window schedule should be shown on the drawings for the new office windows (which <br /> should be shown with dark lines similar to new walls), to include elevations with sill <br /> height. <br /> /5. At least one handrail should be shown on drawings at interior or exterior stairs with <br /> more than four risers, per IPMC section 307. <br /> 9. A new guard should be shown in section at the new upper deck, per IBC section 1013. <br /> v7. Safety glazing should be shown in the following locations, per IBC section 2406.4, to <br /> include: <br /> a. The sliding glass door to the new balcony at the east apartment should be <br /> shown as new on the residential floor, in comparison to the 1994 permit <br /> application plans. <br /> b. The west entrance to the apartment and office. <br /> c. The north entrance and door to the office. <br /> 0A door schedule should be shown on the drawings to include door height, hardware <br /> height, glazing (if any), and hardware that does not require tight grasping, per IBC <br /> section 1008.1.9.1. <br /> 9. ,Please submit a section and details to identify the type and weight of the new materials <br /> used to create a deck area, similar to the details for the new toilet room on the second <br /> floor. <br /> ,/10. Please submit a section and details for the new skylight. <br /> Page 3 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.