. . _ . <br /> 1 , <br /> 459k,77- <br /> MALI( i q 2 ii <br /> iffifirkf i ID • r. <br /> - .•(,--, ,, , r.42) °L <br /> 9 11 1 <br /> COMMERCIAL MECHANICAL AND HOODS <br /> i SUBMITTAL CHECKLIST <br /> pEntri suBiv §.: <br /> 1. Two complete sets of mechanical drawings(1/8"=1'minimum scale) <br /> 2. Maximum size of plan sets: 42" long,30"wide(bound edge), 518"thick. Pages numerically <br /> organized in separate sets that are uniformly sized and stapled. <br /> 3. Minimum site: a measurable scale for review and legible for record. <br /> 4. ,Vechanlical ductwai*should be Shown over a floor plan Of cmidors and rooms, <br /> ' indicating wherefire or smoke dampers are required by the building piens. <br /> 5. Completed Mechanical Permit Application 1 <br /> i 1 6. Type I and Type H hoods should be submitted as separate mechanical permits. NOTE:Type 1 Hoods required where cooking appliances produce grease or smoke. Type I hood <br /> submittals require completed worksheet(attached) along with drawings for review. <br /> Type 11 Ploods required where cooking or dishwashing appliances produce heat or steam but not <br /> grease or smoke. Catalog cuts of equipment served and letter from owner required for all hoods <br /> idoweillmak ,---,. .-- .---, ,....,.:,--,- <br /> I <br /> A. HEATING, VENTILAT/ N &AIR CQ.NpITIONING (HVAC) <br /> 4 I. Size of ducts and outlets; eq4rnerit.sebedule of brand names,fuel type, model numbers, <br /> A <br /> tons of cooling, efficiency rang'; capacity, motor efficiencies, unit weights, economizers or , <br /> - <br /> justification of exceptions and fF.cheduie of smoke and fire dampers. <br /> 2. Combustion or make a;/'30iirCe, -r:•:ize and locations, <br /> 3. Roof parapet and screenind, ,,,There applicable or required. <br /> A 4- Struoteral details and satculations st:,,:imp6d IN a licensed engineer for all suspended or <br /> i <br /> rooftop mechanical units greater than 400:pounds. <br /> i 5. ivianufacturers' installation instru<AionslcOlalog cut sheets for all equipment specified, : <br /> .i <br /> f 6. Compliance with Washington State Energy Code, to include economizers. <br /> B. KITCHEN OR HAZARDOUS EXHAUST:SYSTEM <br /> 1. Exhaust fire detection systems to be identified as integrated with building fire detection if <br /> i automatic detection is required. ., <br /> I <br /> i 2. Building section of ceding/roof ceiling/floor and wall.penetrations by ducts and/or hood& <br /> 3. Minimum clearances to wall or shaft enclosures, including details and tested assemblies <br /> i fire-wrap or other rated enclosures inspections required prior to enclosure, <br /> i 4. Termination outlet distances from adjacent property lines, buildings,tenants, parapets, <br /> grade, openings, supply units,.and roof. <br /> 5. Dedicated make-up air system. <br /> 6. Equipment manufacturer model#for cooking, grease and steam-producing appliances. <br /> 7. Stainless steel (washable, non-combustible)%veil and ceiling treatment shown on elevations <br /> :and reflected ceiling plans. <br /> 8. Hinges required at upblast fans for Type I or Type 11 hoods. <br /> APPLICABLE CODES AND REFERENCES <br /> • Automatic Fire Detection &Suppression Systems Ordinance No. 1902-92 * <br /> • International Building Code(IBC), 2015 Edition&WAG 51-50. <br /> • International Existing Budding Code(1EBC), 2015 Edition&WAG 51-60 <br /> • International Fire Code(IFC),2015 Edition&WAC 51-54 <br /> • international Mechanical Code(1MC),.2015 Edition &WAC 51-52: <br /> ik- Washington State Energy Code (WSEC), 2015 Edition,WAC 51-11 (C, R,Appendix) <br /> 4 Everett Municipal Code, Title 19 Zoning Calst2015-Meclianical re*ecl 06/2017 <br /> CITY OF EVERE7T PERMIT SERVICES 3200 CEDAR ST, EVERETT WA 98201 426-257-8810 <br /> website:www.evereftwa.covlperrnit emaik everettemAsverettwasiov --, <br /> ,,,,,-.,... <br /> , <br /> / <br /> , <br /> i:, ' 1:3 i <br /> . <br /> ,„--- <br /> ----_-- <br />