ki <br />,4419 <br />DESIGN= �I 4lS 2Jp-1'bt �`. � (0-ed) FIELD RE�Qof <br />RT <br />r• <br />Project Name: <br />Everett River Front- Simpson <br />Report: 036 <br />GeoDesign # <br />Pol on-127-03 <br />Date: 05/04/2017 <br />Reports with Unresolved Nonconformance Issues: <br />Permit: <br />PW1505-005 <br />Nick Abdelnour (Polygon) <br />Randy Allen (City of Everett) <br />Weather: Clear, 60's <br />Distribution: <br />Ron Bowen (Polygon) <br />Eddy Stevens (Polygon) <br />Arrival/Departure: 0915/1615 <br />Doug Ross (Polygon) <br />---- <br />Kirk Keck (City of Everett) <br />Paul McKee (City of Everett) <br />Dave Foster (City of Everett) <br />Prepared By. Ben Weinberg <br />Attachments: <br />® Site Plan(s) <br />0 Density Test Summary <br />Signature: ?✓� �� <br />Installation Records <br />Other <br />Reviewed By: <br />PURPOSE of VISIT: GeoDesign representative, Ben Weinberg, was on-site'part time at the request of Craig with DDS to <br />observe the foundation subgrade for Lots 224, 226, and 236. <br />SUMMARY of OBSERVATIONS: <br />Lot 224: <br />Previously, GeoDesign noted that DDS had over -excavated the foundation subgrade area approximately 2.5 feet to 4 feet <br />below bottom of footing and that the southeast corner (-20 feet by 25 feet area) could still be probed 3 feet using a 1/2 Inch <br />diameter soil probe. Today, GeoDesign observed a test pit within southeast corner of the lot area to assess the differing <br />subsurface conditions. <br />GeoDesign noted that large boulders and chunks of concrete mixed with a very moist gray silty SAND with gravel was <br />encountered from approximately 7 to 16 feet below the bottom of footing. The boulders/concrete appeared to have been <br />encapsulated with the surrounding soil and had been subject to an approximately 10 feet surcharge during the pre -loading <br />of Phase 2. At approximately 16 feet below bottom of footing, GeoDesign observed what appeared to be a native gray <br />sandy SILT/gray silty SAND. GeoDesign noted that the test pit excavation was backfilled with the excavated <br />boulders/concrete and silty SAND in a manner which reduced void space between the large boulders/concrete, The <br />material was placed in approximately 1-2 feet lifts which were tamped into place using the bucket of an excavator. <br />GeoDesign recommended that the loose soil in the southeast corner be stabilized by over -excavating the area an additional <br />3 feet and backfilling the area with at least 1.5 feet of quarry spalls tamped into the underlying soil. GeoDesign <br />recommended that the quarry spalls be covered with a non -woven geotextile material. The remaining over -excavated area <br />should be backfilled to bottom of footing elevation with a crushed rock material placed in lifts and compacted into a firm and <br />unyielding mass. <br />At the base of the over -excavated area on the west and north side of the lot area, relative compaction of the exposed soil <br />was tested using a Tmxler Moisture -Density gauge; in -place density tests indicated that the material had been compacted <br />to greater than 95% of its maximum dry density as determined by a Modified Proctor analysis. <br />Craig with DDS stated that the over -excavated area in the southeast comer would be backfilled with quarry spalls starting <br />tomorrow morning. <br />This report prtlsant3 opinlons formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and <br />speclfieallons dtrrntghout the duration of the project Irrespective of the presence of our representative. Our work does not Include supervision or direction of the contractor, the contractor's employees <br />of agents, Our firm is not responsible for site safety. This field report is a DRAIT representation of our field observations, testing, and preliminary recommendations. The report can only be considered <br />Onal upon ravlew of the GaoDesign project manager, as Indicated by initials In the "Reviewed BV'secdon. <br />10700 Meridian Avenue North, Suite 402 1 Seattle, WA 98133 1 206.838.9900 <br />2502 Jefferson Avenue I Tacoma, WA 98402 1 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.