4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
>
Address Records
>
RUCKER AVE
>
4201
>
COMMUNITY HEALTH CENTER
>
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2019 9:26:24 AM
Creation date
3/27/2018 12:05:11 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4201
Tenant Name
COMMUNITY HEALTH CENTER
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
305
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report 7 May 25,2017 <br /> Central Everett CHC,Everett,Washington RGI Project No.2017-094 <br /> Prior to use, a RGI representative should observe and test all materials imported to the <br /> site for use as structural fill. Structural fill materials should be placed in uniform loose <br /> layers not exceeding 12 inches and compacted as specified in Table 3. The soil's maximum <br /> density and optimum moisture should be determined by ASTM D1557. <br /> Table 3 Structural Fill Compaction ASTM D1557 <br /> • <br /> u Nlmrrnum Moisture Content, <br /> Location Material Type Compaction <br /> Range <br /> Foundation backfill Approved imported fill soils 95 +2 -2 <br /> Retaining Wall Backfill Approved imported fill soils 92 +2 -2 <br /> General Fill areas)(non- <br /> Approved imported fill soils 90 +3 -2 <br /> structural..l..—reas..............._......__............_.............................. ... ....................__..........._...........__........._..........._......_....... ......................_............_......................._..................._.__........_.........._......._.._._..................._....._....__.................._......... <br /> Pavement, Subgrade <br /> and Base Course Approved imported fill soils 95 +2 -2 <br /> Placement and compaction of structural fill should be observed by RGI. A representative <br /> number of in-place density tests should be performed as the fill is being placed to confirm <br /> that the recommended level of compaction is achieved. <br /> 5.3 FOUNDATIONS <br /> • <br /> The new building elements can either be supported on shallow or deep foundations as <br /> needed. The design details are presented in the following paragraphs. <br /> 5.3.1 SHALLOW FOUNDATION <br /> Following site preparation and grading, new building element foundations may be <br /> supported on conventional spread footings bearing on medium dense native soil or <br /> structural fill. <br /> Table 4 Foundation Design <br /> Desi n Parameter Value <br /> Allowable Bearing Capacity 2,500 psfl <br /> Friction Coefficient 0.25 <br /> Passive pressure (equivalent fluid pressure) 250 pcf2 <br /> Minimum foundation dimensions Columns: 24 inches <br /> Walls: 16 inches <br /> 1 psf=pounds per square foot <br /> 2 pcf=pounds per cubic foot <br /> II . <br /> RILEYGRUUP <br />