My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
>
Address Records
>
RUCKER AVE
>
4201
>
COMMUNITY HEALTH CENTER
>
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2019-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2019 9:26:24 AM
Creation date
3/27/2018 12:05:11 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4201
Tenant Name
COMMUNITY HEALTH CENTER
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
305
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report 8 May 25,2017 <br /> Central Everett CHC,Everett,Washington RGI Project No.2017-094 • <br /> The allowable foundation bearing pressures apply to dead loads plus design live load <br /> conditions. For short-term loads, such as wind and seismic, a 1/3 increase in this <br /> allowable capacity may be used. At perimeter locations, RGI recommends not including <br /> the upper 12 inches of soil in the computation of passive pressures because it can be <br /> affected by weather or disturbed by future grading activity. The passive pressure value <br /> assumes the foundation will be constructed neat against competent soil or backfilled with <br /> structural fill as described in Section 5.2.5. The recommended base friction and passive <br /> resistance value includes a safety factor of about 1.5. <br /> Perimeter foundations exposed to weather should be at a minimum depth of 18 inches <br /> below final exterior grades. Interior foundations can be constructed at any convenient <br /> depth below the floor slab. Finished grade is defined as the lowest adjacent grade within <br /> 5 feet of the foundation for perimeter (or exterior) footings and finished floor level for <br /> interior footings. <br /> With spread-footing foundations designed in accordance with the recommendations in <br /> this section, maximum total and differential post-construction settlements of 1 inch and <br /> 1/2 inch, respectively, should be expected. <br /> 5.3.2 MicRo PILES <br /> RGI understands that the design team is considering using micro piles to support the <br /> column loads including uplift. <br /> A micro pile is basically vertical soil nail and typically consists of 3/4- to 1-3/8-inch- <br /> diameter steel bars that are centrally grouted in 6- to 8-inch-diameter augered holes. <br /> Based on the soil encountered, a shaft resistance of 1,500 psf can be used for micro pile <br /> design. RGI recommends not including the upper 2 feet of soil in the computation of pile <br /> capacity because it can be affected by weather or disturbed by future grading activity. <br /> The shaft resistance assumes open hole tremie grouting. A pile load test is recommend to <br /> verify the soil resistance before construction. The design capacities listed in Table 5 can <br /> be used in design. The design capacities assume a pile depth of 20 feet bgs. <br /> Table 5 Micro Pile Capacities (kips) <br /> Rrle Typ ,P lCire h amete�(� c ,, o p essi© Uplif6 r l Lateral* ;' <br /> Micro Pile 6 45 42 I 5 <br /> Micro Pile 862 56 6 <br /> *Lateral load assumes 1"top deflection. <br /> II I <br /> l <br /> RILEYGROUP <br />
The URL can be used to link to this page
Your browser does not support the video tag.