W1 Wall mounted linear fluorescent 5 32 160 <br /> X1 Exit sign-EXEMPT 9 <br /> A3.5:All Rooms C2 Recessed downlight CFL 3 42 126 <br /> C2E Recessed downlight CFL w/emergency battery back-up 2 42 84 <br /> C3 Surface mounted CFL 3 32 96 <br /> F2 2x4 recessed 2 lamp direct/indirect fluorescent 66 64 4224 <br /> F2E 2x4 recessed 2 lamp direct/indirect fluorescent 13 64 832 <br /> w/emergency battery back-up <br /> F4 2x4 recessed 2 lamp fluorescent 5 64 320 <br /> R1 Recessed downlight CFL 16 26 416 <br /> R1 E Recessed downlight CFL w/emergency battery back-up 1 26 26 <br /> S5 Decorative ceiling mount fluorescent 3 54 162 <br /> S5E Decorative ceiling mount fluorescent w/emergency 1 54 54 <br /> battery back-up <br /> W4E Wall mounted linear fluorescent 1 32 32 <br /> W5 Decorative fluorescent ceiling mount 2 64 128 <br /> X1 Exit sign-EXEMPT 11 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 18434 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g.T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5 For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />