Laserfiche WebLink
SII OTTO RO* JAU&ASSOCIATES,INC. <br /> REINFORCING STEEL INSPECTION FIELD REPORT <br /> Job Number. 16-0175 Report Number: 356178 Permit Number: PW1505-005 <br /> Project: Riverfront Simpson Client Polygon Northwest <br /> Address: 41st Street and go towards the river Everett,WA Address: 11624 SE 5th St Bellevue,WA <br /> Date: b/26/17 Inspector: Brian R. Robertson WABO SI01181 ICC 0887908-49 <br /> lcirtp�ion <br /> Grade: 60 Manufacturer. Nucor <br /> Type of Bar: ®A-615 0 A-706 0 N/A SDQ Stool: ❑Yes 123 No <br /> Stnicturef Elements./LocatiOrt,f.Odd Liras <br /> On site as requested by the Polygon to inspect reinforcing steel in the Lots 257, and 258 footing walls, HDU's <br /> straps,and interior footings. Inspection of lotS240, 256, and 271.1ooting reinforcing, and 2 electrical UFER grounding <br /> bars per building. Work conforms to the City of Everett approved pans and the current IRC Code. <br /> *wanly; Ix Daes•Not conform.] <br /> Is this a re-inspection? 0 Yes ®No Start Time: 10:30am Finish Time: 12:30pm <br /> Original inspection date: First inspection by: <br /> Inspected by: L , Reviewed by: <br /> This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau&Associates,Inc. Reproduction of this report, <br /> except in full,without written permission from our firm is strictly prohibited. <br /> Page of <br /> 6747 M.L.King Way S.,Seattle,Washington 98118-Phone(206)725-4600 or 1-888-OTTO-4-US—Fax(206)723-2221 <br /> Form No.:INSP--76-03 LT(Rev 03/08) E ' <br />