My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4418 31ST AVE SE 2018-03-28
>
Address Records
>
31ST AVE SE
>
4418
>
4418 31ST AVE SE 2018-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2018 1:40:16 PM
Creation date
3/28/2018 1:40:13 PM
Metadata
Fields
Template:
Address Document
Street Name
31ST AVE SE
Street Number
4418
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEIDESIGN FIELD REPQ <br /> 2 of ) <br /> Project Name: Everett River Front-Simpson Report: 056 <br /> GeoDesign#: Polygon-127-03 Date: 07/14/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> _ .,,. .. . <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather: Clear, 60-70's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 0945/1230 <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Ben Weinberg <br /> Attachments: m Site Plan(s) 0 Density Test Summary Signature: 0f%.-.- <br /> 0 Installation Records 0 Other Reviewed By: <br /> SUMMARY of OBSERVATIONS (CONTINUED): <br /> LOT 271: <br /> Today, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 271. Previously, <br /> GeoDesign observed the removal of unsuitable fill material from 8-10 feet below bottom of plan footing within the building <br /> area and replacement with structural fill material. Today, GeoDesign noted that exposed foundation subgrade material <br /> consisted of a gray-brown silty SAND with gravel which could generally be probed less than 2 inches using a 1/2 inch <br /> diameter soil probe. <br /> It is the opinion of GeoDesign that the exposed foundation subgrade observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any surficially loose and/or saturated material be removed from the base <br /> of the foundation area prior to the placement of concrete. <br /> LOT 272: <br /> Today, GeoDesign noted that DDS had completed excavation of the footing and crawl space area for Lot 272. Previously, <br /> GeoDesign observed the removal of unsuitable fill material from 8-10 feet below bottom of plan footing within the building <br /> area and replacement with structural fill material. Today, GeoDesign noted that exposed foundation subgrade material <br /> consisted of a gray-brown silty SAND with gravel which could generally be probed less than 2 inches using a 1/2 inch <br /> diameter soil probe. <br /> It is the opinion of GeoDesign that the exposed foundation subgrade observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any surficially loose and/or saturated material be removed from the base <br /> of the foundation area prior to the placement of concrete. <br /> A summary of our observations and density tests taken today can be found in the attached Figure 1. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 I Seattle,WA 98133 I 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 I 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.