Laserfiche WebLink
x r <br /> Interior Lighting Su, ,nary - Building Area Med LTG-INT-BLD <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Anytime Fitness Date 1/5/2016 <br /> Lighting Alterations,Renovations &Building Additions" For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance.Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Building Area types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Building Area types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d.If less than 60%of existing fixtures will be replaced,use LTG-INT-SPACE form. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Gross Interior Watts Allowed <br /> Building Area* room#,or ALL) Area Description Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Exercise center All 0.8.8 6001 5281 <br /> Exercise center 0.88 <br /> Exercise center 0.88 <br /> * Select Table C405.5.2(1)Building Area from drop down menu. Total' 6001 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> Building Area* room#) Fixture Description** Fixtures Fixture Proposed <br /> Exercise center All Indirect/Direct LED 54 48 2592 <br /> Exercise center Existing Restroom Surface Mounted Fluorescent 2 64 128 - <br /> Exercise center New Restrooms Recessed LED can lights 6 11 66 <br /> Exercise center Lobby 8'linear track 8 50 400 <br /> * Select Table C405.5.2(1)Building Area from drop down menu. <br /> **Include existing to remain lighting and exempt lighting equipment per notes below. <br /> Compliance by Building Area <br /> Total Allowed Total Proposed Interior Lighting Power <br /> Building Area Warnings Watts Watts Allowance <br /> Exercise center 5281 3186 COMPLIES <br /> Total 5281 I 3186 <br /> Notes: <br /> 1.Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between <br /> Building Area types is not allowed under the Building Area Method compliance path. <br /> 2.Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. <br /> 3.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 4.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices or of the transformer.For low voltage track lighting list the transformer rated wattage. „v°''` <br /> 5.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. d" <br /> c n...............t....:..L:.....a...........:..4:..a.......:..n.. J 1:..,a:....t..1.1..:..41..........,...........................[:..s....... 5.J....a:�.........;..4:....:..C...a......J........:..a:..... <br />