My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1523 132ND ST SE ANYTIME FITNESS 2018-03-29
>
Address Records
>
132ND ST SE
>
1523
>
ANYTIME FITNESS
>
1523 132ND ST SE ANYTIME FITNESS 2018-03-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2018 9:45:15 AM
Creation date
3/29/2018 9:45:11 AM
Metadata
Fields
Template:
Address Document
Street Name
132ND ST SE
Street Number
1523
Tenant Name
ANYTIME FITNESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f i <br /> Lighting, Motor, and " insformer Permit DocumeL Checklist LTG-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Anytime Fitness Date 1/5/2016 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and transformer requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component -Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS(Section C405.2) <br /> C405.2.1.1 Manual interior Indicate on plans the manual control type&locations served; • <br /> C405.2.1.2 lighting controls Indicate of plans the 50%lighting load reduction method <br /> provided or identify exception taken <br /> Indicate lighting system automatic shut-off capability-identify <br /> lighting zone areas served on plans; <br /> Automatic time Indicate locations of override switches on plans and the areas <br /> C405.2.2.1 switch controls and <br /> override switching served,include area sq.ft.; <br />• Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor,daylight controls,etc) <br /> C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors <br /> Daylight zones- Indicate vertical fenestration primary and secondary daylight <br /> C405.2.2.3 Vertical fenestration zone areas on plans,include sq.ft.; <br /> and skylights Indicate skylight daylight zone areas on plans,include sq.ft. <br /> Daylight zone Indicate on plans the locations served by daylight zone controls; <br /> C405.2.2.3.2 controls <br /> Indicate in plans the lighting load reduction(dimming)method- <br /> stepped or continuous dimming <br /> Specific application Indicate on plans the locations served by specific application <br /> C405.2.3 lighting controls- <br /> General lighting controls <br /> Indicate lighting control method for display and accent lighting, <br /> C405.2.3- Display and accent <br /> and display case lighting; <br /> Items 1&2 lighting Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the • <br /> same space <br /> C405.2.3- Hotel/motel guest Provide a lighting control device at each guest room entry for all <br /> Item 3 rooms permanently installed fixtures in guest room; <br /> Indicated whether lighting control is manual or automatic . <br /> C405.2.3- Supplemental task Provide automatic shut-off vacancy controls for supplemental <br /> Item 4 lighting task lighting,including under-shelf or under-cabinet lighting <br /> Identify eligible non-visual applications and method of lighting <br /> C405.2.3- Lighting for non- <br /> control; <br /> Item 5 visual applications Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the <br /> same space <br /> Indicate lighting control method for lighting equipment for sale <br /> C405.2.3- Lighting equipment or demonstration; <br /> Item 6 for sale or Indicate these fixtures are controlled independently from both <br /> demonstration general area lighting and other lighting applications within the <br /> same space <br /> If egress lighting power density is greater than 0.05W/ft2, <br /> C405.2.3- Means of egress indicate method of automatic shut-off during unoccupied <br /> Item 7 lighting periods; <br /> Identify on plans the egress fixtures that function as both normal <br /> and emergency means of egress illumination <br /> C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 <br /> C405.11 lighting minutes of unoccupancy for cooler and freezer lighting fixtures <br /> with lamp efficacy less than 40 lumens per watt <br /> C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control <br /> controls method and locations served <br /> Exterior building Provide motion sensor controls for building grounds fixtures <br /> C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 <br /> controls lumens,or identify exception taken <br /> Identify applicable commissioning documentation requirements <br /> per Section C408 or eligibility for exception; <br /> C408.3 Lighting system Provide written procedures for functional testing of all automatic <br /> functional testing controls and describe the expected system response; <br /> Identify in construction documents the party responsible for <br /> _. <br /> functional testing of automatic lighting controls <br /> INTERIOR LIGHTING POWER&EFFICACY(Sections C405.5,C405.10, C405.11) �'! , <br />
The URL can be used to link to this page
Your browser does not support the video tag.