My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 100TH ST SW AURORA DOOR 2018-03-30
>
Address Records
>
100TH ST SW
>
2201
>
AURORA DOOR
>
2201 100TH ST SW AURORA DOOR 2018-03-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2018 2:44:27 PM
Creation date
3/30/2018 2:44:23 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
2201
Tenant Name
AURORA DOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAYES TESTING ENGINEERS, INC 2 alley <br /> =i- Road <br /> Site 110 <br /> Lynnwood,WA 98036 <br /> Project No. L16474 ph425.742.9360 <br /> Project Aurora Systems Inc. fax 425.745.1737 <br /> /.mess`— 9—2201 100th SW, Everett, WA Tacoma Office <br /> ,� Permit No. B1601-0210029 S.Tacoma Way <br /> (s_ 31dg Dept. City of Everett sUteE-2 <br /> Tacoma,WA 98499 <br /> F_ ph 253.584.3720 <br /> Client Aureus LLC fax 253 584.3707 <br /> Engineer West Coast Structural Engineering Portland Office <br /> Contractor GLY Construction Co. Inc. 7911 NE 33rd Drive <br /> Site 190 <br /> Portland,OR 97211 <br /> ph 503.281.7515 <br /> Record No. 002 fax 503.281.7579 <br /> Date 08/12/16 <br /> Weather Clear <br /> Inspection Welding-visual <br /> Sample(s) N/A <br /> Onsite for visual inspection of single pass fillet welds. Inspector unable to verify welder <br /> certifications. The 1/4" fillet welds at grid lines 2/I, J, K, K.2 HSS column to bucket per detail S5.0/5 <br /> were found to be acceptable per AWS D1.1. <br /> Simpson Ties to beam welded at grid line 1, the following discrepancies were noted: <br /> 1. Need clarification of weld detail; inspector provided with manufacturer's recommendations, <br /> but not official weld detail. <br /> 2. Simpson Ties at columns, grid lines 1/K.5 and J.5 had added metal welded to column face <br /> and bottom of tie, due to column interference. <br /> l <br /> 77k41 <br /> y. <br /> O.\ 1 if . ,,. i <br /> 1..k <br /> f .- <br /> Figurel. Photo shows top of Figure 2. Photo of added plate noted above. <br /> Simpson Tie welded to beam. <br /> PRELIMINARY INSPECTION <br /> Inspector: Tim York <br /> Reviewed By: <br /> 414. <br /> dirdp, <br /> Robert Gardner <br /> Senior Project Manager <br /> Information in this report applies only to the actual items inspected or tested and shall not be reproduced except in full,without the approval of Mayes Testing Engineers,Inc. <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.