Laserfiche WebLink
1.25-Year 102.497 <br /> 2.00-Year 102.816 <br /> 3.33-Year 103.037 <br /> 5-Year 103.075 <br /> 10-Year 103.110 <br /> 25-Year 103.141 <br /> 50-Year 103.169 <br /> 100-Year 103.202 <br /> ***********Groundwater Recharge Summary************* <br /> Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures <br /> Total Predeveloped Recharge During Simulation <br /> Model Element Recharge Amount(ac-ft) <br /> Subbasin: Subbasin 1 162.230 <br /> Total: 162.230 <br /> Total Post Developed Recharge During Simulation <br /> Model Element Recharge Amount(ac-ft) <br /> Subbasin: Subbasin 1 64.164 <br /> Link: Detention Pond 0.000 <br /> Total: 64.164 <br /> Total Predevelopment Recharge is Greater than Post Developed <br /> Average Recharge Per Year, (Number of Years= 158) <br /> Predeveloped: 1.027 ac-ft/year, Post Developed: 0.406 ac-ft/year <br /> ***********Water Quality Facility Data************* <br /> SCENARIO: PREDEVELOPED <br /> Number of Links: 0 <br /> SCENARIO: POSTDEVELOPED <br /> Number of Links: 1 <br /> ********** Link: Detention Pond ********** <br /> Basic Wet Pond Volume (91% Exceedance): 7068. cu-ft <br /> Computed Large Wet Pond Volume, 1.5*Basic Volume: 10602. cu-ft <br /> Infiltration/Filtration Statistics <br /> Total Runoff Volume (ac-ft): 763.30 <br /> Total Runoff Infiltrated (ac-ft): 0.00, 0.00% <br /> Total Runoff Filtered (ac-ft): 0.00, 0.00% <br /> Percent Treated (Infiltrated+Filtered)/Total Volume: 0.00% <br />