My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9700 HOLLY DR 2017 Plans 2022-12-06
>
Address Records
>
HOLLY DR
>
9700
>
Plans
>
9700 HOLLY DR 2017 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 8:01:45 AM
Creation date
4/13/2018 8:22:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9700
Permit
B1704-038
Year
2017
Notes
ACES ALTERNATIVE HIGH SCHOOL REPLACE PORTABLE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � <br /> m a` <br /> o � � <br /> � <br /> � d- <br /> . � W � <br /> � a � <br /> 00 � N <br /> � <br /> � <br /> � <br /> 1.0 RflOF F►SSY: `O <br /> J <br /> - ROOFING: PABCO"PREMIER"ARCHITECTURAL SHINGLE (INSTALL PER �-~- p � <br /> HIGH WIND APPLICATION WSTRUCTIONS) � t= <br /> -WEATHERPROOFING: (2) LAYERS OF 151b CLASS B FELT(APPLIED SHINGLE STYLE � � ¢ <br /> UNDER ROOFING) INSTALL ICE AND WATER SHIELD UNDEFi SHINGLES FOR � C3 � <br /> 24° FROM INSIDE WALL LWE AT EACH EAVE TOWARD RIDGE � � I— <br /> -SHEATHING: 7/16"OSB PANELS, FASTEN PER STRUCTURAL SUMMARY � o O <br /> -MATELINE BEAM: (1)1.5"x24" LVL EACH SIDE OF MATELINE. FASTEN LVL FACE TO 0 � <br /> FACE ON SITE W/SDS SCREWS OR M.B. PER STRUCTURAL SUMMARY � <br /> - FfiAMING: 2x12 HF-2 RAFTERS Qa 24"O.C. INNER ENDS SUPPORTED BY 2x LEDGER U <br /> OUTER ENDS SEAT CUT&SUPPOFiTED BY EXTEftIOR WALL TOP PLATE <br /> - RIM JOISTS: (1)1.5"x7.25°LVL(CONTINUOUS) &2x10 VENT BLOCKS PER DETAIL T o <br /> - INSULATION: R-38c FIBERGLASS BATTS(UNFACED) Z <br /> -AIR BARRIER: GRIP RITE"E" HOUSEWORK(ASTM E-2178&ASTM E-84-CLASS A <br /> -CEILING: SUSPENDED CEILING GRID(2x4 GRID)WI ARMSTRONG °CORTEGA"#769A <br /> CEILING TILES. INSTALL CEILWG PER IBC SECTION 808,ASTM C 635, & � <br /> ASTM C 636. IN PLACE OF WALL ANGLE, INSTALL ARMSTRONG BERK CI.IPS L� <br /> �' � ON TWO ADJOINING WALLS. RIVET CROSS TEES TO OPPOSITE WALL A(JGLES � <br /> � ENSURE SITE INSTALLED GROSS TEES AT MATELINE ARE SECURELY FASTENED <br /> -SOFFIT: HARDI-SOFF[T AT UNDERSIDE OF RAFTER TAILS. (PERFORATED AT EAVES � <br /> SOLID AT GABLE ENDS) 16"OVERHANG TYP ALL SIDES E-- <br /> -FASCIA&BARGE: 1x6 FWGER JOINTED CEDAR m <br /> -GUTTERS& D/S: 5" PREFINISHED GUTTERS WI(4)2"fZ�PVC DOWNSPOUTS IN FACTORY � � � <br /> I I ❑ <br /> � 2.0 EXTERI�R WALL ASSY: U T o <br /> c� z � m <br /> EXTERfOR SIDE (AL�WALLS): � � ¢ z � m <br /> -EXTERIOR TRIM: FWGER JOINTED ROUGH SAWN CEDAR. w � °- � � o <br /> � -CORNERS: 1 x4 W/2°x2°GALVANIZED FLASHING INSTALLED OVER w z r�- � W = , <br /> � RIDGECAP(SHIPLOOSE) I SIDING AND UNDER TRIM � � "� � � � <br /> — I � -MATE�INE: 1x4 SHIPLOOSE <br /> - DOORS&1NINDOWS: 1x4 <br /> � — 12� T6��6�� � - FLASHING: Z- FLASHING AT BOTTOM OF SIDWG &HORIZONTAL BREAK LINE AT END WALLS � � <br /> II � � REFER TO FLASHING PROFILE ON STRUCTURAL DETAIL PAGE � � <br /> � -SIDING: 5/16" HARDI-PANEL W/GROOVES Qa 8"O.C. � � <br /> � 1.� RODFiCEILING ASSY � -BUILDWG WFiAP: GRIP RITE°E"HOUSEWRAP, INSTALL PER MFR INSTRUCTIONS, UTILIZE TAPES AND � <br /> 3„ � ��-0" � SEALANTS RECOMMENDED IN THE INSTALLATION INSTRUCTIONS. � � C� <br /> '� - EXTERIOR INSULATION:1/2"THICK POLYISO RIGID INSULATION � (f� <br /> � I -SHEATHING: 7/16"OSB PANELS, FASTEN PER SHEAR WALL REQUIREMENTS IN STRUCTURAL � � � � <br /> � SUMMARY. � <br /> -FRAMING: 2x6 HF-STUD�a 16"O.C. (DOUBLE STUDS AT VERTICAL SIDWG EDGES) (� <br /> � � I FRAME PER PRESCRIPTIVE INTERMEDIATE FRAMING METHOD — r � � ` <br /> -TOP PLATE: 1.5"x5.5°LVL CONTINUOUS (END WALLS USE 2x6 HF-2) p� � � <br /> � - BOTTOM PLATE: 2x6 HF-STUD �) � <br /> � -WSULATION: R-21 FIBEFiGLASS BATTS, UNFACED (FILL CAVITY OF ANY PLUMBING WALLS) � � � '' , ' • <br /> — 1 INTERIOR SIDE WALL W1A: �1 <br /> ( -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED � � � <br /> — — T/Plate -COVERING: 1/2"TACKBOARD (RELIEF CUT ABOVE/BELOW WINOOWS& DOORS) INSTALL � � <br /> — — — — — — — — — — — — — � — _ 1 � <br /> �1�_4�� � � 8� - ��� � VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � � � <br /> � F/CI 1 INTERIOR SIDE WALL W1 B: � U O� <br /> CEILING GRID � -SUBSTRATE: 5/8 GWB(TYP X) UNFINISHED � � � <br /> " ' H� - O�� -COVERING: 5.8 GWB TAPE,TEXTURED,& PAINTED � � � � <br /> I INTERIOR SIDE WALL W1C: � <br /> I � -S U B S T R A T E: 5/8°G W B (T Y P E X) S Q U A R E E D G E, U N F I N I S H E D � <br /> -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO � � � <br /> � � � 1/4° PLYWOOD BACKING � — � � <br /> ,� � -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS(FASTEN W/SCREWS) � � C,� <br /> � "' INTERIOR SIDE WALL W1 D: � � (� � <br /> M \ -SHEATHING: 7/16"OSB PANELS � � � <br /> ( � � 2.0 EXTERIOR WALL -covFRiNG: 5is"GWB(TYP X)TAPE,TEXTURED, & PAINTED � <br /> 3.0 INTERIOR WALL ASSY (y CI� � <br /> w <br /> � 3.0 INTERI�R WALL ASSY: z u <br /> � W w <br /> W z o ¢ <br /> "" I WALL W2A: o w w � <br /> \. <br /> -COVERING: 1(2"TACKBOARD (RELIEF CUT ABOVEIBELOW WINDOWS& DOORS) INSTALL c~n p o w . <br /> VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � � � � <br /> a � -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED <br /> '- - FRAMWG: 2x4 HF-STUD @16"O.C., SINGLE 2x4 TOP AND BOTTOM PLATES(FULL HEIGHT) � <br /> N � - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (FILL CAVITY OF ANY PLUMBING WALLS) o � <br /> 4.0 FLOOR ASSY LAUNDRY ROOM ONLY, REMAINEDER UNISULATED � z <br /> \ � �� -SUBSTRATE: 5/8"GWB (TYPE X) SQUAFiE EDGE, UNFINISHED � `� <br /> � -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO z o"'o w <br /> — ��— 1 _ Floor 1 � 1/4"PLYWOOD BACKWG p 6' �n-' . <br /> O O -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS(FASTEN W/SCFiEWS) r � � �_ <br /> — — B/I V I O C I 1 l� WALL W2B: Y o u.� �? �`'-� <br /> i ' i — � �� -TRIM: 1"WIDE FLAT ALUMINUM 8AR AT SEAMS AND CORNERS(FASTEN W/SCREWS) � � � �� � <br /> � � -O - � 1�4 -COVERING: NIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO �z c i o �� <br /> � � 1/4"PLYWOOD BACKING °'��' ° "' '� <br /> i i -SUBSTRATE: 5/8°GWB(TYPE X) SQUARE EDGE, UNFINISHED � o Q =a m <br /> ,- m� � � � <br /> — � � Grade \ -FRAMING: 2x4 HF-STUD @16"O.C. SINGLE 2x4 TOP AND BQTTOM PLATES (FULL HEIGHT) <br /> -SUBSTRATE: 5/8"GWB(TYPE X) SQUARE EDGE, UNFINISHED <br /> SKIRTING MATERIAL PACKAGE ' � I -2' - 2 1/4�� � -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO <br /> 1/4" PLYWOOD BACKING ■ <br /> SHIP LOOSE(EXCEPT FRAMtNG) P.T. FRAMING FOR SKIRTING -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND COFiNERS (FASTEN W(SCREWS) <br /> BYOTHERS ON S1TE(N.B.W.) WALL W2C: <br /> -COVERING: 5/8°GWB(TYP X)TAPE,TEXTURED, & PAINTED <br /> 1 ���� '�+\J�p�� ��r+���A) -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED � cn <br /> � Y �� �r� ��� - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER � � z <br /> ` 1/2"= 1'-0" UNINSULATED) o • <br /> - FRAMING: 2x4 HF-STUD @16"O.C., SINGLE 2x4 TOP AND BOTTOM PLATES (FULL HEIGHT) - � <br /> - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER O7 - <br /> UNINSULATED) � ¢ <br /> -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED �' � <br /> -COVERING: 1/2"TACKBOARD (RELIEF CUT ABOVE/BELOW WINDOWS& DOORS) INSTALL � p <br /> VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � <br /> WALL W2D: � <br /> -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS (FASTEN W!SCREWS) ¢ <br /> -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO � <br /> 1/4°PLYWOOD BACKING 00 <br /> -SUBSTRATE: 5/8°GWB(TYPE X) SQUARE EDGE, UNFINISHED � � <br /> -FRAMING: 2x4 HF-STUD @16"O.C. SINGLE 2x4 TOP AND BOTTOM PLATES (FULL HEIGHT) <br /> - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER <br /> UNINSULATED) <br /> -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED <br /> � -COVERING: 5/8°GWB(TYP X)TAPE,TEXTURED, & PAINTED ��a � � � ��� � � <br /> � � �� 4 <br /> �\�\����V'`�\�� a� � <br /> ��������� � � � . <br /> # � �.��� <br /> ��ti°<, r <br /> � <br /> ���� � � <br /> � � <br /> 4.0 FLOOR ASSY; � ���� <br /> - BASE TRIM: WSTALLED ON SITE 8Y OTHERS � ���`�� � �s�.c� <br /> - F I N I S H F L O O R: I N S T A L L E D O N S I T E B Y O T H E R S ���� . � <br /> - UNDERLAYMENT: 1/4"ULTRAPLY XL(EXCEPT AT EMERGENCY SHOWER) <br /> -DECKING: 3/4"STURD-I-FLOOR APA FiATED T&G PANELS(GLUED AND NAILED) � w z <br /> , - FRAMING: 2x8 HF-2 JOISTS�a 16"O.C. W/JOIST HANGERS EA END. �� u�� w z <br /> - RIM JOISTS: 1.5°x7.25" LVL CONTINUOUS. NOTE: INSTALL 12"TALL MOISTURE BARRIER ¢ � � =W �o Q <br /> AROUND BUILDING PERIMETER � o Q o� W ,.,_� <br /> - INSULATION: (2)LAYERS R-15 FIBERGLASS BATTS � n. v � = w � � <br /> - UNDERCLOSURE; CLASS A WOVEN POLYETHYLENE FABRIC �w z �� r � _ � <br /> z � zo� wm � <br /> �J � <br /> � �w U z � z p . <br /> ap�o�� dcWr� <br /> zw � �� cn� <br /> QCCW � — UW <br /> c� =} � wzo� <br /> z <br /> � �ww �- wzcr <br /> ¢ z -� mcnWcno <br /> p ¢= 0w� � 1-=- <br /> � ~ � � � � <br /> �z� E- a wcna <br /> = o� ox > cnz <br /> HUOZW W <L � <br /> JOB NUMBER: <br /> 4305 . <br /> SHEET No.: <br /> ���.0 . <br /> DATE: <br /> 7.15.16 <br /> SCALE: As indicated <br />
The URL can be used to link to this page
Your browser does not support the video tag.