Laserfiche WebLink
� <br /> � <br /> m a` <br /> o � � <br /> � <br /> � d- <br /> . � W � <br /> � a � <br /> 00 � N <br /> � <br /> � <br /> � <br /> 1.0 RflOF F►SSY: `O <br /> J <br /> - ROOFING: PABCO"PREMIER"ARCHITECTURAL SHINGLE (INSTALL PER �-~- p � <br /> HIGH WIND APPLICATION WSTRUCTIONS) � t= <br /> -WEATHERPROOFING: (2) LAYERS OF 151b CLASS B FELT(APPLIED SHINGLE STYLE � � ¢ <br /> UNDER ROOFING) INSTALL ICE AND WATER SHIELD UNDEFi SHINGLES FOR � C3 � <br /> 24° FROM INSIDE WALL LWE AT EACH EAVE TOWARD RIDGE � � I— <br /> -SHEATHING: 7/16"OSB PANELS, FASTEN PER STRUCTURAL SUMMARY � o O <br /> -MATELINE BEAM: (1)1.5"x24" LVL EACH SIDE OF MATELINE. FASTEN LVL FACE TO 0 � <br /> FACE ON SITE W/SDS SCREWS OR M.B. PER STRUCTURAL SUMMARY � <br /> - FfiAMING: 2x12 HF-2 RAFTERS Qa 24"O.C. INNER ENDS SUPPORTED BY 2x LEDGER U <br /> OUTER ENDS SEAT CUT&SUPPOFiTED BY EXTEftIOR WALL TOP PLATE <br /> - RIM JOISTS: (1)1.5"x7.25°LVL(CONTINUOUS) &2x10 VENT BLOCKS PER DETAIL T o <br /> - INSULATION: R-38c FIBERGLASS BATTS(UNFACED) Z <br /> -AIR BARRIER: GRIP RITE"E" HOUSEWORK(ASTM E-2178&ASTM E-84-CLASS A <br /> -CEILING: SUSPENDED CEILING GRID(2x4 GRID)WI ARMSTRONG °CORTEGA"#769A <br /> CEILING TILES. INSTALL CEILWG PER IBC SECTION 808,ASTM C 635, & � <br /> ASTM C 636. IN PLACE OF WALL ANGLE, INSTALL ARMSTRONG BERK CI.IPS L� <br /> �' � ON TWO ADJOINING WALLS. RIVET CROSS TEES TO OPPOSITE WALL A(JGLES � <br /> � ENSURE SITE INSTALLED GROSS TEES AT MATELINE ARE SECURELY FASTENED <br /> -SOFFIT: HARDI-SOFF[T AT UNDERSIDE OF RAFTER TAILS. (PERFORATED AT EAVES � <br /> SOLID AT GABLE ENDS) 16"OVERHANG TYP ALL SIDES E-- <br /> -FASCIA&BARGE: 1x6 FWGER JOINTED CEDAR m <br /> -GUTTERS& D/S: 5" PREFINISHED GUTTERS WI(4)2"fZ�PVC DOWNSPOUTS IN FACTORY � � � <br /> I I ❑ <br /> � 2.0 EXTERI�R WALL ASSY: U T o <br /> c� z � m <br /> EXTERfOR SIDE (AL�WALLS): � � ¢ z � m <br /> -EXTERIOR TRIM: FWGER JOINTED ROUGH SAWN CEDAR. w � °- � � o <br /> � -CORNERS: 1 x4 W/2°x2°GALVANIZED FLASHING INSTALLED OVER w z r�- � W = , <br /> � RIDGECAP(SHIPLOOSE) I SIDING AND UNDER TRIM � � "� � � � <br /> — I � -MATE�INE: 1x4 SHIPLOOSE <br /> - DOORS&1NINDOWS: 1x4 <br /> � — 12� T6��6�� � - FLASHING: Z- FLASHING AT BOTTOM OF SIDWG &HORIZONTAL BREAK LINE AT END WALLS � � <br /> II � � REFER TO FLASHING PROFILE ON STRUCTURAL DETAIL PAGE � � <br /> � -SIDING: 5/16" HARDI-PANEL W/GROOVES Qa 8"O.C. � � <br /> � 1.� RODFiCEILING ASSY � -BUILDWG WFiAP: GRIP RITE°E"HOUSEWRAP, INSTALL PER MFR INSTRUCTIONS, UTILIZE TAPES AND � <br /> 3„ � ��-0" � SEALANTS RECOMMENDED IN THE INSTALLATION INSTRUCTIONS. � � C� <br /> '� - EXTERIOR INSULATION:1/2"THICK POLYISO RIGID INSULATION � (f� <br /> � I -SHEATHING: 7/16"OSB PANELS, FASTEN PER SHEAR WALL REQUIREMENTS IN STRUCTURAL � � � � <br /> � SUMMARY. � <br /> -FRAMING: 2x6 HF-STUD�a 16"O.C. (DOUBLE STUDS AT VERTICAL SIDWG EDGES) (� <br /> � � I FRAME PER PRESCRIPTIVE INTERMEDIATE FRAMING METHOD — r � � ` <br /> -TOP PLATE: 1.5"x5.5°LVL CONTINUOUS (END WALLS USE 2x6 HF-2) p� � � <br /> � - BOTTOM PLATE: 2x6 HF-STUD �) � <br /> � -WSULATION: R-21 FIBEFiGLASS BATTS, UNFACED (FILL CAVITY OF ANY PLUMBING WALLS) � � � '' , ' • <br /> — 1 INTERIOR SIDE WALL W1A: �1 <br /> ( -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED � � � <br /> — — T/Plate -COVERING: 1/2"TACKBOARD (RELIEF CUT ABOVE/BELOW WINOOWS& DOORS) INSTALL � � <br /> — — — — — — — — — — — — — � — _ 1 � <br /> �1�_4�� � � 8� - ��� � VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � � � <br /> � F/CI 1 INTERIOR SIDE WALL W1 B: � U O� <br /> CEILING GRID � -SUBSTRATE: 5/8 GWB(TYP X) UNFINISHED � � � <br /> " ' H� - O�� -COVERING: 5.8 GWB TAPE,TEXTURED,& PAINTED � � � � <br /> I INTERIOR SIDE WALL W1C: � <br /> I � -S U B S T R A T E: 5/8°G W B (T Y P E X) S Q U A R E E D G E, U N F I N I S H E D � <br /> -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO � � � <br /> � � � 1/4° PLYWOOD BACKING � — � � <br /> ,� � -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS(FASTEN W/SCREWS) � � C,� <br /> � "' INTERIOR SIDE WALL W1 D: � � (� � <br /> M \ -SHEATHING: 7/16"OSB PANELS � � � <br /> ( � � 2.0 EXTERIOR WALL -covFRiNG: 5is"GWB(TYP X)TAPE,TEXTURED, & PAINTED � <br /> 3.0 INTERIOR WALL ASSY (y CI� � <br /> w <br /> � 3.0 INTERI�R WALL ASSY: z u <br /> � W w <br /> W z o ¢ <br /> "" I WALL W2A: o w w � <br /> \. <br /> -COVERING: 1(2"TACKBOARD (RELIEF CUT ABOVEIBELOW WINDOWS& DOORS) INSTALL c~n p o w . <br /> VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � � � � <br /> a � -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED <br /> '- - FRAMWG: 2x4 HF-STUD @16"O.C., SINGLE 2x4 TOP AND BOTTOM PLATES(FULL HEIGHT) � <br /> N � - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (FILL CAVITY OF ANY PLUMBING WALLS) o � <br /> 4.0 FLOOR ASSY LAUNDRY ROOM ONLY, REMAINEDER UNISULATED � z <br /> \ � �� -SUBSTRATE: 5/8"GWB (TYPE X) SQUAFiE EDGE, UNFINISHED � `� <br /> � -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO z o"'o w <br /> — ��— 1 _ Floor 1 � 1/4"PLYWOOD BACKWG p 6' �n-' . <br /> O O -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS(FASTEN W/SCFiEWS) r � � �_ <br /> — — B/I V I O C I 1 l� WALL W2B: Y o u.� �? �`'-� <br /> i ' i — � �� -TRIM: 1"WIDE FLAT ALUMINUM 8AR AT SEAMS AND CORNERS(FASTEN W/SCREWS) � � � �� � <br /> � � -O - � 1�4 -COVERING: NIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO �z c i o �� <br /> � � 1/4"PLYWOOD BACKING °'��' ° "' '� <br /> i i -SUBSTRATE: 5/8°GWB(TYPE X) SQUARE EDGE, UNFINISHED � o Q =a m <br /> ,- m� � � � <br /> — � � Grade \ -FRAMING: 2x4 HF-STUD @16"O.C. SINGLE 2x4 TOP AND BQTTOM PLATES (FULL HEIGHT) <br /> -SUBSTRATE: 5/8"GWB(TYPE X) SQUARE EDGE, UNFINISHED <br /> SKIRTING MATERIAL PACKAGE ' � I -2' - 2 1/4�� � -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO <br /> 1/4" PLYWOOD BACKING ■ <br /> SHIP LOOSE(EXCEPT FRAMtNG) P.T. FRAMING FOR SKIRTING -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND COFiNERS (FASTEN W(SCREWS) <br /> BYOTHERS ON S1TE(N.B.W.) WALL W2C: <br /> -COVERING: 5/8°GWB(TYP X)TAPE,TEXTURED, & PAINTED <br /> 1 ���� '�+\J�p�� ��r+���A) -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED � cn <br /> � Y �� �r� ��� - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER � � z <br /> ` 1/2"= 1'-0" UNINSULATED) o • <br /> - FRAMING: 2x4 HF-STUD @16"O.C., SINGLE 2x4 TOP AND BOTTOM PLATES (FULL HEIGHT) - � <br /> - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER O7 - <br /> UNINSULATED) � ¢ <br /> -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED �' � <br /> -COVERING: 1/2"TACKBOARD (RELIEF CUT ABOVE/BELOW WINDOWS& DOORS) INSTALL � p <br /> VINYL WRAPPED BATTS AT RELIEF CUTS, MATELINE&CORNERS � <br /> WALL W2D: � <br /> -TRIM: 1"WIDE FLAT ALUMINUM BAR AT SEAMS AND CORNERS (FASTEN W!SCREWS) ¢ <br /> -COVERING: HIGH PRESSURE LAMINATE(NOT CHEMICAL RESISTANT) PRE-LAMINATED TO � <br /> 1/4°PLYWOOD BACKING 00 <br /> -SUBSTRATE: 5/8°GWB(TYPE X) SQUARE EDGE, UNFINISHED � � <br /> -FRAMING: 2x4 HF-STUD @16"O.C. SINGLE 2x4 TOP AND BOTTOM PLATES (FULL HEIGHT) <br /> - INSULATION: R-11 FIBERGLASS BATTS, UNFACED (LAUNDRY ROOM WALLS ONLY, REMAINDER <br /> UNINSULATED) <br /> -SUBSTRATE: 5/8"GWB(TYPE X) UNFINISHED <br /> � -COVERING: 5/8°GWB(TYP X)TAPE,TEXTURED, & PAINTED ��a � � � ��� � � <br /> � � �� 4 <br /> �\�\����V'`�\�� a� � <br /> ��������� � � � . <br /> # � �.��� <br /> ��ti°<, r <br /> � <br /> ���� � � <br /> � � <br /> 4.0 FLOOR ASSY; � ���� <br /> - BASE TRIM: WSTALLED ON SITE 8Y OTHERS � ���`�� � �s�.c� <br /> - F I N I S H F L O O R: I N S T A L L E D O N S I T E B Y O T H E R S ���� . � <br /> - UNDERLAYMENT: 1/4"ULTRAPLY XL(EXCEPT AT EMERGENCY SHOWER) <br /> -DECKING: 3/4"STURD-I-FLOOR APA FiATED T&G PANELS(GLUED AND NAILED) � w z <br /> , - FRAMING: 2x8 HF-2 JOISTS�a 16"O.C. W/JOIST HANGERS EA END. �� u�� w z <br /> - RIM JOISTS: 1.5°x7.25" LVL CONTINUOUS. NOTE: INSTALL 12"TALL MOISTURE BARRIER ¢ � � =W �o Q <br /> AROUND BUILDING PERIMETER � o Q o� W ,.,_� <br /> - INSULATION: (2)LAYERS R-15 FIBERGLASS BATTS � n. v � = w � � <br /> - UNDERCLOSURE; CLASS A WOVEN POLYETHYLENE FABRIC �w z �� r � _ � <br /> z � zo� wm � <br /> �J � <br /> � �w U z � z p . <br /> ap�o�� dcWr� <br /> zw � �� cn� <br /> QCCW � — UW <br /> c� =} � wzo� <br /> z <br /> � �ww �- wzcr <br /> ¢ z -� mcnWcno <br /> p ¢= 0w� � 1-=- <br /> � ~ � � � � <br /> �z� E- a wcna <br /> = o� ox > cnz <br /> HUOZW W <L � <br /> JOB NUMBER: <br /> 4305 . <br /> SHEET No.: <br /> ���.0 . <br /> DATE: <br /> 7.15.16 <br /> SCALE: As indicated <br />