W <br /> � <br /> m � <br /> o m � <br /> � ��„ <br /> co W � <br /> co ~ � <br /> co � N j . <br /> � <br /> r <br /> � <br /> � <br /> NOTES: r� � � Q <br /> 0 0 � o � <br /> GEtVERAL: � � W I m a Q <br /> 1. A L L H E I G H T D I M E N S I O N S S H O W N O N P L A N A R E F R O M F I N I S H F L O O R T O C E N T E R O F B O X W z = � ~ <br /> UNLESS NOTED OTHERWISE � NOTE:WHITLEY SCOPE OF WORK IS � � � <br /> LIMITED TO 1�VITHIN UTILITY ROOM 102 � o � <br /> 2. ITALICS INDICATES WORK TO BE DONE ON SITE(BY OTHERS UNLESS OTHERWISE NOTED) MDP WITH THE EXCEPTION OF STUBBING � J <br /> 225 A FEEDER CONDUIT FROM PANEL MDP t- � <br /> 3. SERVICE ENTRANCE IS ON SITE BY OTHERS,WHITLEY TO PROVIDE PANEL WITH CONDUIT � 1201208 THRU FLOOR INTO JOIST CAVITY. Branch Panel. � <br /> DOWN INTO FLOOR CAVITY, EXTENSION OF CONDUIT, INSTALLATION OF FEEDER 22Kaic EXTENSION OF CONDUIT TO METER/POINT OF � <br /> CONDUCTORS, ALL OTHER SERVICE DISCONNECTS,TRANSFORMERS, BOXES AND CONDUIT ARE CONNECTION AND INSTALLATION OF FEEDER Location: UTILITY 102 Volts: 120/208 Single A.I.C. Rating: 10000 <br /> ON SITE BY OTHERS. CONDUCTORS Supply From: Phases: 1 Mains Type: BREAKER ,-. z <br /> I ARE ON SITE BY OTHERS UNDER SEPARATE Mounting: Recessed Wires: 3 Nlains Rating: 200 A <br /> 4. ALL ELECTRICAL CONSTRUCTION MEANS AND METHODS SHALL COMPLY WITH NEC 2014 225A M.B. LOCAL PERMIT. Encloswre: NEMA 1 MCB Rating: 200 A <br /> EDITION,AND WAC 296-46B ) N.L.E.A. � <br /> 5. ALL RECEPTACLES SHALL BE INSTALLED AT 18"AFF UNLESS NOTED OTHERWISE. Notes: Wc <br /> G <br /> 6. GROUND FAULT(GFCI) PROTECTION IS REQUIRED FOR ALL RECEPTACLES IN WET AREAS. _ UTILITY 102 O I <br /> EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT,AND INSTALLED WITH A IN-USE I <br /> COVER. CRAWL SPACE <br /> � <br /> 7. BUILDING SHALL BE WIRED IN CONDUIT OR MC CABLE � - <br /> = m <br /> I #2 GND TO COLD CKT Circwit Descriptian Trip Poles A B Poles Trip � Circuit Description CKT U T p <br /> 8. A L L C O N D U C T O R S, C O N D U I T S A N D C I F i C U I T S S H A L L B E S I Z E D T O C O M P L Y W I T H N E C 2 0 1 4. 2,.C W A T E R P I P E& 1 S p a c e -- � -- 0 VA 0 VA � p ,� ;, -- -- 'S pace 2 � z .. � <br /> MW WIRE SIZES. � GROUND ROD 3 S ace -- 0 VA 0 VA -- -- Space I 4 w `� z m o y: <br /> POWER AND LIGHTING CIRCUITS -MIN. 12 AWG N.L.E.A. (2)#4/0 HOT P --, ¢ o J z m <br /> � (1)#2/0 NEUT. 5 CLOTHES DRYER RECEPTACLE 30 A 2 2250�/A 250Q:UA 2 35 A WATEFi HEATER (ROOM 102) 6 11J a � cWi_� o <br /> B R A N C H C I R C U I T H O M E R U N S O V E R 7 5 F E E T -M I N. 1 0 A W G <br /> , _ a <br /> I N C O M I N G S E R V I C E F E E D E R (1)#2 GND. 7 -- 2 2 5 0 V A ;2 5 Q 0 V A; -- -- -- . 8 w z � � w �_ <br /> CONTROL WIRING -MIN. 14 AWG I -" ����- � <br /> BY OTHERS � �� � � �� <br /> 9 CLOTHES WASHER RECEPTCLE 20 A 1 �.`1200;11A 12QO�VA� 1 20 A DISHWASHER 10 <br /> 9. ALL INDICATED WIRE SIZES BASED ON 75 DEGREE EQUIPMENT TERMINAL RATINGS IN ACCORDANCE 11 WATER NEATER (ROOM 100) 20 A 1 �:�'� '��. " 1�OOaVA���:�OQ UA,; 1 20 A �FUME HOOD EXHAUST FAN � 12 � <br /> � WITH NEC 310-16. WHERE EQUIPMENT IS PROVIDED AT LESS THAN 75 DEGREE, CONTRACTOR � � � � � O <br /> SHALL PROVIDE PROPER CONDUCTOR SIZE ADJUSTED ACCORDINGLY TO REFLECT EQUIPMENT 13 LIGHTING - INTiEXTIEGRESS 20 A 1 1172 VA 420 VA 1 20 A FUME HOOD RECEPTAC�ES AND LIGHT 14 1 � 1 <br /> � RATINGS, AVAILABLE FAULT CURRENT � 15 GENERAL RECEPTACLE (6) RM 102, 103 20 A 1 �� 1080 VA �1080 VA� 1 20 A GENERAL RECEPTACLE (6) RM 101, 103 ig � LL.1 <br /> p �+ LESS THEN 10 Kaic ' <br /> ELECTRICA� RI�,7ER 17 IGENERAL RECEPTACLE (5) RM 100 20 A 1 ti720 VA 540 VA ; ����, ` 1 20 A GENERAL RECEPTACLE (2) RM 100 18 W � � � � <br /> ������� 19 GENERAL RECEPTACLE (4) RM 100 � 20 A 1 -�� �720 VA 360�UA�`; 1 20 A GENERAL RECEPTACLE (3) RM 100 20 � � (f� Cl� <br /> 1 I 21 �GENERAL RECEPTACLE (2), REFER (1) RM 101 20 A 1 "t7s0 UA 180,;VA I 1 20 A Receptacle 22 � (f) <br /> � 114"= 1'-0" 23 ' � ` 4 ` �� �° 24 � � � � <br /> � 25 � _ � ���� 26 � � � � <br /> 27 �- i 28 <br /> � <br /> 29 � ���;� � 3� O = � . <br /> < . <br /> ,� ._�_-. _... <br /> � 32 � � � � <br /> 31 � ; �� ���.�;' <br /> LIGHTING NOTES: 33 � � � ` � ( 34 <br /> - U � <br /> 37 I .....� .�9 : : ' ,�- 36 \ <br /> � <br /> 1. LIGHTING SHALL COMPLY WITH WASHINGTON STATE ENERGY CODE(WSEC)2015 EDITION. I . .; ' -.-�� � 38 � � W � <br /> 2. EACH SPACE ENCLOSED BY WALLS OR CEILING HEIGHT PARTITIONS SHALL BE PROVIDED WITH LIGHTING CONTROLS LOCATED WITHIN 3g ; ° �s j 40 _ (,� U <br /> THAT SPACE.THE LIGHTING CONTROLS, WHETHER ONE OR MORE, SHALL BE CAPABLE OF TURNING OFF ALL LIGHTS WITHIN THE SPACE. 41 I 42 � C� Z <br /> THE CONTROLS SHALL BE READILY ACCESSIBLE,AT THE POINT(S)OF ENTRY/EXIT. (EXCEPTION: LIGHTING CONTROLLED BY AUTOMATIC m"`' "" '` <br /> Total Load: � 10942 VA� 9990 VA W W <br /> CONTROLS) (WSEC C405.2.1.1) � � U � <br /> 3. LIGHT REDUCTION CONTROLS NEED NOT BE PROVIDED DUE TO CONTROL VIA AN OCCUPANCY SENSOR(WSEC C405.2.1.2 EXC.2) Total Amps: 104 A 96 A <br /> 4. AUTOMATIC TIME SWITCH CONTROL DEVICES NOT REQUIRED DUE TO CONTROL VIA AN OCCUPANCY SENSOR. (WSEC 405.2.2.1 EXC. 2) Legend: � -� (n � <br /> 5. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED 16 <br /> AMPERES. A MASTER CONTROL MAY BE PROVIDED AS LONG AS THE INDIVIDUAL SWITCHES RETAIN THE ABILITY TO FUNCTION W � C� <br /> INDEPENDENTLY(WSEC C405.2.5) � � � J <br /> 6. THE INTERIOR OCCUPANCY SENSING AUTOMATIC CONTROL DEVICES SHALL BE INSTALLED TO AUTOMATICALLY TURN OFF ALL LIGHTS Laad Classification Connected Load Demand Factor Estimated �emand Pane)Totals <br /> WITHIN 30 MINUTES OF ALL.OCCUPANTS LEAVING THE SPACE,AND SHALL EITHER BE MANUAL ON OR SHALL BE CONTROLLED TO �Equipment 14220 VA � 100.00% 14220 VA �O <br /> AUTOMATICALLY TURN THE LIGHTING ON TO NOT MORE THAN 50 PERCENT POWER(WSEC C405.2.2.2) - Q � (V W <br /> 7. ALL EXTERIOR LIGHTING NOT REQUIRED TO REMAIN ON 24 HOURS CONTINUOUS, SHALL BE CONTROLLED BY A PHOTOCELL(WSEC Lighting 1173 VA 125.00% 1467 VA Total Conn. Load: 20933 VA <br /> C405.2.4) Motor I 500 VA 125.00% 625 VA Total Est. �emand:I21352 VA � � ti I <br /> 8. THESE AUTOMATIC CONTROL DEVICES SHALL BE INSTALLED TO AUTOMATICALLY TURN OFF ALL LIGHTS WITHIN 30 MINUTES OF ALL Other j 0 VA 0.00% 0 VA Total Conn.: 101 A z ¢ W ! w <br /> OCCUPANTS LEAVING THE SPACE,AND SHALL EITHER BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING 5040 VA Total Est. Demand: 103 A <br /> Receptacle 5040 VA 100.00% W � � Q <br /> O N T O N O T M O R E T H A N 5 0 P E R C E N T P O W E R (W S E C C 4 0 5.2.22) � � � z <br /> 9. DAYLITE ZONES SHALL BE CONTROLLED INDEPENDENTLY FROM GENERAL AREA LIGHTING. EACH DAYLIGHT CONTROL ZONE SHALL NOT I o w w E- <br /> EXCEED 2,500 SQUARE FEET. CONTIGUOUS DAYLIGTH ZONES ADJACENT TO VERTICAL FENESTRATION ARE ALLOWED TO BE CONTROLLED c~i> o o w <br /> BY A SINGLE CONTROLLING DEVICE PROVIDED THAT THEY NOT INCLUDE ZONES FACING MORE THAN TWO ADJACENT CARDINAL = � � _ <br /> ORIENTATIONS(WSEC C405.2.2.3 Notes: <br /> � � � <br /> 10. AUTOMATIC DAYLIGHT CONTFiOLS SHALL BE PROVIDED TO REDUCE THE LIGHTING POWER IN � <br /> 0 <br /> 11. THE DAYLIGHT ZONES CONTINUOUSLY TO A MAX. OF 20%FULL POWER(WSEC C405.2.2.3.2) � � <br /> � z <br /> m Q <br /> z Nm �' . <br /> � w <br /> �� <br /> � � � �_ <br /> YoW "' �;�' <br /> O '� � � c�o� <br /> �z j � o� <br /> cn � ci co� <br /> rn � � � <br /> �� r� .. m <br /> rm � �� � <br /> LIGHTING BUDGET CALCULATIONS <br /> MAXIMUM ALLOWED INTERIOR LIGHTING WATTAGE (SPACE BY SPACE METHOD) ■ <br /> LIGHTItdG FIXTURE SCHEDULE SPACETYPE AREA VA/SF VAALLOWED � <br /> e Z <br /> ; . LAMP(S) INPUT CLASSROOM 1,479 1.00 1,479 � � <br /> MARK QTY ' DESCRIPTION MFR. MODEL QTY TYPE WATTS BALLAST ELECTRICAL DATA COMMENTS � UTILTY OOM 169 o.4a 335 � � � <br /> L-1 18 2x4 LAY-IN LED TROFFER LITHONIA 2GTL4-60-EZ1-LP850 1 LED 55 VA LED DRIVER 120 V/1-55 VA W/PRISMATIC DIFFUSER � � � <br /> TOTAL VA ALLOWED 1,667 VA � � 0° <br /> L-2 4 UNDER CABINET FLUORESCENT STRIP LIGHT LITHONIA UC 24E 2 8W-T5 �21 VA ELECTRONIC 120 V/1-21 VA , ' � � <br /> ¢ <br /> L-3 4 EXT. FLUORESCENT LIGHT,WALL MOUNT TBD T.B.D 2 2-PL 26 VA ELECTRONIC 120 V/1-26 VA ROUGH IN ONLY, FIXTUFiES BY OWNER (WHITLEY TO LIGHT REDUCTION/REDUCED LIGHTING POWER (PER WSEC C406.1 #2) � � <br /> PFiOViDE CENTRAL PHOTOCELL � � o <br /> L-4 4 LIGHTED EXIT SIGN, SINGLE SIDED - UNIVERSAL MOUNT LITHONIA LE-S-W-1-G-ELN-SD LED 5 VA LED DRIVER 120 V/1-5 VA W/MINUMUM 90 MIN. BATTERY BACKUP, REFER TO PLAN TOTAL VA ALLOWED x 0.75= 0.75 x 1,667 = 1250 VA ALLOWED PEFi = � <br /> FOR MOUNTWG&ARROWS SECTION C408 ADDITIONAL EFFICIENCY OPTIONS � ¢ <br /> � L-5 1 EGFiESS LIGHT, BUG EYE,WALL MOUNTED MFR. STD. MFR. STD. 2 LED 5 VA 120 V/1-5 VA � � w <br /> PROPOSED INTERIOR LIGHTING WATTAGE � p <br /> (18) LED TROFFERS @ 54.8 VA 986 <br /> / � <br /> (4) FLOURECENT U/C STRIP LIGHTS C� 21VA 84 � <br /> (4) LED EXIT SIGNS C�5VA 20 <br /> TOTAL PROPOSED INTERIOR LIGHTING VA 1,090 VA ��` <br /> �S��°� •` � � ' <br /> �G .. . r�2 _£ <br /> MAXIMUM ALLOWED EXTERIOR TRADABLE LIGHTING WATTAGE: �� ` <br /> � � <br /> TRADABLE SURFACE WATTS/LF LF VA ALLOWED <br /> ` � v. � <br /> MAIN ENTRY 30 6 180 � � , �� <br /> OTHER ENTRIES 20 9 60 � � <br /> BASIC SITE ALLOWANCE ZONE 3 750 <br /> � <br /> TOTAL VA ALLOWED 990 o W o � } � � � <br /> Qdz �w �� Q <br /> PROPOSED EXTERIOR LIGHTING WATTAGE: �� `��� w " o <br /> oWz~� w� v� <br /> � �� _ <br /> , (4) WALL MOUNT FLOUFiESCENT FIXTURES @26VA 104 z � z o� ,.,.,m � <br /> J - <br /> TOTAL PROPOSED LIGHTING VA 104 Q �� �o =z � <br /> ooc� o � 'S �uWi <br /> zw � �� cn � <br /> QCLw � - UW <br /> W > a � z � o <br /> �2wwrs - w <br /> z rcCwzON <br /> � � ww� wZOC <br /> pQ = 0wC3� O <br /> t-- ~ [C CC �� <br /> v�z � � � wcn¢ <br /> = o� Ox > cnz <br /> I-C�Ozww ¢ � <br /> JOB NUMBER: <br /> 4305 <br /> SHEET No.: <br /> E-0.0 <br /> DATE: <br /> 7.15.16 <br /> SCALE: 1/4" = 1'-0" <br />