Laserfiche WebLink
COMPRESSED AIR PIPE SYSTEM SPECIFICATION: _`�� J . OLS <br /> - PIPING SHALL BE 3/4" DIAMETER COPPER PIPE TYPE K OR TYPE L �.�.0���,0� ��'Bf�,GO�, <br /> - PIPING CONNECTIONS SHALL BE BY SOLDER OR COMPRESSION CONNECTION � '� � <br /> - PIPING SYSTEM SHALL BE SECURED APPROPRIATELY AT A 8 FOOT OR LESS SPACING <br /> VALVES: .i <br /> - USE BALL VALVES EXCLUSIVELY UNLESS OTHERWISE SPECIFIED �'�'o .e '�' o .�v� <br /> - BALL VALVES SHALL BE BY A SINGLE MANUFACTURER �' ��SSIONAL���� <br /> - VALVES SHALL BE TWO PIECE FULL PORT RATED FOR 150 PSI OR HIGHER. '� <br /> - BRONZE BODY, SS BALL, 150 PSIG AT 70 DEG. F � <br /> - TEFLON SEALS OR TEFLON TAPE SHALL BE USED; BUBBLE TIGHT AT 100 PSIG UNDERWATER �' <br /> G90 GALVANIZED STEEL DUCTING w <br /> MAKE-uP AIR 0.028 IN MIN. NOMINAL THICKNESS INSTALLATION: � . <br /> INLINE FAN, 8" DUCT FACILITY EXTERIOR WALL PER IMC TABLE 510.8 °' <br /> GREENHECK DAMPER INSTALL PER MFG. INSTRUCTIONS 1 HR FIRE RATED ABOVE - DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND � <br /> 3RD FLOOR � ARRANGEMENT OF COMPRESSED AIR PIPING. INSTALL PIPING AT RIGHT ANGLES OR a. <br /> FSDR-511 DUCT JOINTS TO BE TIGHT WITH A <br /> COMBfNED FIRE AND 10" to s" ROUND REDUCER MIN. 1 iN LAP. PARALLEL TO WALLS. INSTALL PIPING ADJACENT TO EQUiPMENT TO ALLOW FOR SERVICE c� J <br /> SMOKE, �.5 HR RATE� � AND MAINTENANCE. INSTALL PIPING FREE OF SAGS AND BENDS. INSTALL FITTINGS FOR � <br /> OR SIMILAR R7.7 INSULAl1NG WRAP TO EXTRACTION � Q <br /> WSTALLATION PER MFG. ROOM. � CHANGES W DIRECTION AND BRANCH CONNECTIONS. �„ > <br /> INSTRUCTIONS <br /> LOCATE NEAR FUME HooD N EXHAUST FAN COVER WITH REDUCING <br /> VERIICAL INSTALLATION i 8 DUCT TO EXTRACTION ROOM PIPING TESTING: O <br /> SHOWN. FACILITY EXTERIOR WALL � <br /> - PRESSURIZE COMPLETED PIPING SYSTEM TO 50 PSI OR LESS. �, � <br /> CANARM 5010-XPF - AT EVERY JOINT APPLY SOAPY WATER AT JOINT. IDENTIFY AND RECORD ANY BUBBLE N � <br /> Q � � WALL FAN FORMATION AND THE JOINT LOCATION. CONTINUE TO EACH JOINT. o � <br /> INSTALL PER MFG. INSTRUCTIONS � Q <br /> SECURE PER MANUFACTURER — REPAIR ANY RECORDED LEAKING JOINTS � <br /> INSTRUCTIONS <br /> 18" SUPPLY LOUVER (1000 CFM) � <br /> INSTALL PER MFG. INSTRUCTIONS � <br /> -t-. <br /> ,� <br /> � <br /> S" ROUND DUCT TO RECTANGULAR � <br /> ADAPTER. CUSTOM ADAPTER PLATE -� m � <br /> ROOM CEILING SEE MFG. INSTRUCTIONs FACILITY FLOOR, 2 HR FIRE RATED � � W 0 <br /> FIRE RESISTANT SEA�ANT AT ALL SEE DETAIL 4, SHEET S1.0 � � � � <br /> PENETRATIONS � [ r— <br /> (USG TYPE FC 1/2" MIN.) '— W � 00 <br /> OR SIMILAR � C Z � � <br /> �l1 � <br /> � <br /> Q ���� d Q � � <br /> �- ��� lJ � d- <br /> � 0 = <br /> o Q � � t1j <br /> N <br /> DETAIL VIEW - EXTRACTION ROOM SUPPLY VENTILATION DETAIL VIEW - EXTRACTION ROOM EXHAUST VENTILATION DETAIL � � N � � <br /> c � <br /> 1 2 �3 SCALE: 1/4- = r-o• o � � <br /> son�: ,�4• = r-o• �.,— � � i <br /> � � Y <br /> � � <br /> � <br /> � <br /> c <br /> 0 <br /> � � <br /> 0 <br /> � <br /> � <br /> � c_ <br /> � Z <br /> � OO <br /> � Z <br /> -o � � <br /> o � Q <br /> � W z � <br /> � � Q <br /> z <br /> NEW COMPRESSOR W <br /> � � <br /> � � _ � <br /> �, � � w <br /> �� COMP. AIR LINE � � <br /> M 1.1 �' � t� <br /> w <br /> cn � <br /> a�'.� � Q <br /> SUPPLY 1 � Q � <br /> 100 PSI � � � � <br /> � � Q' �-~-' <br /> � N W <br /> 17 �7 SUPPLY LINE FILTER � � <br /> PARKER 07F44BC w <br /> SUPPLY LINE BALL W <br /> M1.1 M1.1 SHUT OFF VALVE GRAINGER PN 21U823 �+- <br /> 3/4" 3/4" NPT, 145 CFM T <br /> � <br /> � <br /> EXT. ROOM AUX. ROOM 16 �. <br /> SUPPLY 3 SUPPLY 2 M�.� � <br /> 100 PSI 100 PSI <br /> � - COMPRESSOR SIDE FLOW � � <br /> � <br /> -�-� <br /> SUPPLY LINE REGULATOR •`f' <br /> PARKER R119-06CG/M2 3/4" NPT COPPER FITTING <br /> GRAINGER PN 21U841 TYPICAL � <br /> � � <br /> 3/4" NPT, SET TO 100 PSI � N N O1 <br /> \ \ \ <br /> M M d� <br /> � <br /> � <br /> O <br /> .N <br /> � w <br /> � � ¢ <br /> q DETAIL - COMPRESSED AIR SYSTEM RISER DIAGRAM �6 DETAIL - COMPRESSED AIR SUPPLY AT COMPRESSOR <br /> � � <br /> 15 SCALE: NTS SCALE: NTS �_ � � <br /> O � � x <br /> z <br /> Z � <br /> � � � � � <br /> � W w � � <br /> � 0 � o � <br /> PLAN VIEW - COMPRESSED AIR SUPPLY <br /> � o 0 <br /> 14 scn�: ,/a. _ ,•-04 � � � � Z <br /> � N � o <br /> � F <br /> C!� � t� <br /> � � Q ¢ <br /> C _ Z N � <br /> � 3/4'SUPPLY LINE �O.� <br /> FRON CONPRESSOR � L— <br /> � SUPPLY UNE REGULATOR . . <br /> PARKER R119-OBCG/lA2 � � <br /> . . � � � � �-' �' � <br /> GRAWf,�F2 PN 21U841 . . . . . � -� (\J �: \ O O <br /> %4'EQNUPT�,SET TO 100 PSI . O � (� �N N � � . <br /> s/ti•enu vuv� �- J J <br /> W � o \ <br /> � `� w � � <br /> s/�•�FlrnNo •� � . � Q � p <br /> cn Q Q � Z W <br /> c z Z W Y <br /> Cr � c.� <br /> Wlq(qSCONNECT . . . � � . � Q—C!'�j m J � Q W <br /> FlrnNo -� � L� � � U <br /> � <br /> 'MREADED PLUC . � � C <br /> CLEM!-WT � d <br /> C1� <br /> 0 <br /> :� SHEET <br /> � <br /> � <br /> � <br /> � <br /> � <br /> � <br /> • <br /> � <br /> � <br /> � <br /> DETAIL — COMPRESSED AIR CONNECTION AT POINT OF USE � <br /> 1� SCALE: Ni5 U <br /> � OF � SHEETS <br /> -.� <br /> � <br /> � <br /> �-- <br />