My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2916 STATE ST 2016 CRIMSONEYE FARMS Plans 2022-12-06
>
Address Records
>
STATE ST
>
2916
>
CRIMSONEYE FARMS
>
Plans
>
2916 STATE ST 2016 CRIMSONEYE FARMS Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 8:02:36 AM
Creation date
4/13/2018 9:32:01 AM
Metadata
Fields
Template:
Address Document
Street Name
STATE ST
Street Number
2916
Tenant Name
CRIMSONEYE FARMS
Permit
B1603-038
M1603-020
Year
2016
Notes
ADD ROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EL.ECTRICAL SPECIFICATION: <br /> PER NFPA 70 ARTICLE 500 AND ARTICLE 501 - CLASS 1 DIVISION 2 LOCATION _`�� d •OLS� <br /> NATIONAL ELECTRICAL CODE ,�0��,aF �'�8i,�� <br /> - NON-EXPLOSION PROOF DEVICES ALLOWED PER SECTION 500.7(K) INTEGRATED GAS DETECTION � ��e �� � <br /> EXTRACTION ROOM - TYPE MC (INSTALLED AT >= 10 FT), MV, TC OR TC-ER CABLE, TERMINATED WITH LISTED FITTINGS <br /> r CONTROL PANEL AND <br /> CLASS 1 DIV. 2 ZONE AT TOF - FLEXIBLE CONNECTIONS USING TYPE MC, LIQUIDTIGHT METAL FLEX WITH LISTED FITTINGS . <br /> q-HVDC BATTERY BACKUP - NONINCENDIVE FIELD WIRING PERMITTED AS UNCLASSIFIED. ,� -� � <br /> TO 18�� TOF PER NFPA 497 EMERGENCY POWER SYS. - BOXES, FITTINGS NOT REQUIRED TO BE EXPLOSION PROOF WHEN OUTLETS AND ENCLOSURES � ���'�S��G79�T8�$��1� <br /> BOUNDARY SEALS REQUIRED TO CONTAINING NON-ARCING DEVICES. GENERAL PURPOSE ENCLOSURE WSTALLED WITH RIGID, � SI�NAL � <br /> .� <br /> PNL ER-001 FLEXIBLE, OR INTERMEDIATE METAL CONDUIT, A BONDING JUMPER WITH PROPER FITTINGS OR a, <br /> PREVENT VAPOR COMMUNICATION BONDING TYPE LOCKNUTS REQUIRED TO BE USED BETWEEN ENCLOSURE AND CONDUIT/RACEWAY � <br /> EXTRACTION ROOM ALAR �� <br /> LARSON ELECTRONICS - coNou�-r RUN LEAVING DIVISION 2 LOCATION SHALL INCLUDE BOUNDARY SEAL WITHIN 10 FT OF <br /> w <br /> EITHER SIDE OF BOUNDARY (CLASS 1 DIV 2 TO UNCLASSIFIED LOC), c�ii <br /> M1 HALP-24-2L-LED-NL-SFC � <br /> - CONDUIT ENTERING EXPLOSION PROOF ENCLOSURES SHALL INCLUDE A CONDUIT SEAL WITH SEAL o <br /> --� � CLASS 1 DIV. 2 LIGHT ASSY SEALING COMPQUND PER SEAL OFF MANUFACTURER INSTRUCTIONS. �- <br /> z ,o, � . <br /> - ALL ELECTRICAL EQUIPMENT TO BE LISTED (UL/ ETL) _,..� � <br /> - OPEN OR NON EXPLOSION PROOF ENCLOSED MOTORS WITHOUT BRUSHES, SWITCHING ELEMENTS, �°'„ Q <br /> OR SIMILAR ARC PRODUCING DEVICES NOT IDENTIFIED FOR USE IN CLASS 1 DIV 2 LOCATIONS w � <br /> FACILITY BREAKER PANEL ,0\ EMERG. PWR OUTLET SHALL BE PERMITTED. DEVICES TO BE CONFIRMED BY ENGINEER OF RECORD PRIOR TO o O <br /> GFCI AND LIGHT iNs-ra��aTioN. � � <br /> 0 <br /> - INSTALLATION OF PORTABLE UTILIZATION DEVICES IS ALLOWED PER SECTION 501.140 (A)(1) WITH N � <br /> ;O; � <br /> INSTALLATION PER SECTION 501.140(B) 1 THROUGH 4 0 <br /> � Q� <br /> O �O, � <br /> , , CLASS 1 DIV. 2 RATED � <br /> � <br /> PNL ER-001 GAS„DETECTION SENSOR .� � <br /> 3/4 THREADED CONDUIT � <br /> CLASS 1 DIV. 2 SEAL OFF � m �- <br /> � � c wo <br /> PNL ER-001 � �' � � <br /> p '� C � � � <br /> 120VAC � <br /> M2 EMERGENCY POWER FOR EXTRACTION PROCESS ° c z � � <br /> INVERTER BATTS SHALL ACTIVAT Q- ��`�► � '� <br /> E AUTOMATICALLY � � � a Q � �, <br /> � ��� o = � d- <br /> AND PROVIDE 2 HRS POWER BEYOND SHUTD�WN o a o � � <br /> REQUIREMENTS � <br /> � � N � d- <br /> C � <br /> � � � � <br /> tJI I� .L <br /> � � � <br /> � <br /> V W - ELECTRICAL PLAN � <br /> 1� SCALE. 3/8" m 1' 0' <br /> i <br /> O <br /> Q� <br /> O <br /> � <br /> � <br /> .� <br /> � z . <br /> � O <br /> � � <br /> � z <br /> —� � _ <br /> ( ll � <br /> _�__+ V J Q <br /> � W Z � <br /> � � z <br /> -� W � <br /> � <br /> � _ � <br /> � <br /> •� I— w <br /> � w <br /> 24 VDC POWER SUPPLY PROCESSING AREA � <br /> FROM FACILITY � � � <br /> MAIN PANEL 60 WATT CONTROL PANEL 1-PA .� � , <br /> MULIIPLE SOURCES 120Y/120A (n <br /> � � <br /> W <br /> FU-2�9 CIRCUIT 1 W <br /> 24VDC TO COMBUSTI6LE � � Q <br /> GAS DETECTOR <br /> 2A P� p Q ~ <br /> � <br /> � � <br /> � <br /> CR302 <br /> � � � � <br /> cR1o6 REMOVE POWER � N W <br /> AT EVENT � <br /> W � . <br /> ���� REMOVE POWER p W <br /> AT EVENT <br /> � <br /> � <br /> CRt14 REMOVE POWER � <br /> AT EVENT � • <br /> i <br /> CRtta REMOVE POWER Q-- . <br /> AT EVENT <br /> N <br /> ^� <br /> —+.� <br /> C!7 <br /> zawc(+) Q; <br /> GND <br /> U <br /> �� � � � � <br /> FlELD � Q \ a�o a <br /> SPLICE/ JB � M M d�- <br /> CR126 ROOM LIGHT <br /> LIGHT SWITCH � / � _ <br /> O LIGHT CIRCUIT 7 (� <br /> O <br /> 2PDT / \ (120V/20A) •� "- �p <br /> TO PROCESSING 1 <br /> AREA CIRCUITS Q- U � � <br /> EMERc. Pw� cR�2s AND DETECTOR o � � Z <br /> DISCONNECT SW � W p a <br /> CR122 <br /> CIRCUIT 8 FANAusT ESSENTIAL PROCESS ENGR. n' v� � � <br /> � � J o <br /> INVERTER M'� PN: EPS1000 OR EQUAL <br /> 48 VDC/ 24QOW -{-�' � � W � <br /> 120VAC/100A � o � <br /> � o <br /> 0 <br /> 3oA 4.sA FROM MAIN � � � � Z <br /> SUPP�Y � O � � o <br /> CR122 ciRcuiT s FAN PANEL N � <br /> EMERGENCY POWER � � Q � a <br /> M 2 120VAC/125A <br /> + _ DISCONNECT PANEL BREAKER PANEL � ? N � <br /> 4.2A � � �� <br /> � z o N <br /> 24VDC(+) L ALARM NO LT 2 • <br /> � O � � � <br /> BATT. PACK CIRCUIT 9 � / ROOM ALARM � <br /> DISCONNECT SW �� � AUTOMAl10N DIRECT p � 3 � Z Z <br /> I / \ PN: 2051005 � <br /> U N � � oo <br /> Q o o c� (n tn <br /> � o Q � � � J J <br /> FAC. AUDIBLE ALARM � � N � ¢ � Q <br /> 60A {' - + - AUTOMATION DIRECT LL_ <br /> 12VDC 12VDC PN: 48205255 <br /> 1 0 0 Amp H R 1 0 0 Amp H R �r s W V E R T E R/B A T T A S S Y Q N I—' O Q � w <br /> � � 4 X 12VDC BATTS IN � � x z Z W � � <br /> AUTIOMAl10N DIRECT CR1 GFCI SERIES ��'��r � CO •� W � J (n � _ <br /> / � PN: 2051005 �°� �°� (120V/20A) � � � N � U <br /> TO EXT. 24VDC(+) , , �, 36" CLEAR IN FRONT � <br /> ROOM + - + - 2PDT O Q EXIRACTION - � <br /> OUTLETS 12�p� 12VDC EMERG. PWR �M�,��� �M��� OF PANELS 00 � <br /> 100 AmpHR 100 AmpHR � � EMERGENCY LIGHT � a <br /> ACIIVATED BY BATf. GFCI LOCATE OUTSIDE � <br /> , � P� cR2 I � SHEET <br /> EXTRACTION ROOM ;� � <br /> �,� �,� � <br /> (1 ZOV/ZOA) ,reo M,.r,wo ww. ,z,ao M,a.neo.rx� <br /> EMERGENCY OUTLET 2PDT �°� �°� EXTRACTION � <br /> �e� 120 VAC/10 AMP p <br /> � ' <br /> 120VAC(+) � <br /> -+--% <br /> a.� <br /> � <br /> �SINGLE LINE DIAGRAM �SINGLE LINE DIAGRAM CONTINUED ,,, ELEVATI.ON VIEW - PANEL INSTALLATION/ EMERGENCY POWER � OF � SHEETS <br /> SCALE: NTS G V SCALE: NTS L� SCALE: NTS -� <br /> C/� <br /> � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.