Mr.Tony Lee, Building Official <br /> July 17, 2017 <br /> 2160819.01,Task 03 <br /> Page 2 of 3 <br /> da All doors serving the assembly uses (with occupant loads greater than 50) from the exit <br /> access through to the exits should be shown with panic hardware (if the doors have locks <br /> or latches). Section <br /> Response: Drawings have been updated to note that panic hardware is required per <br /> Section 1010.1.10 of the 2015 IBC. <br /> Exit signs should be shown at each exit door. Section <br /> Response: Exit signs are located on Sheets A1.03 and A1.04. Additional exit signs <br /> have been added to Rooms 210 and 211. <br /> Emergency egress lighting should be shown within the room. Section <br /> Response: Emergency lighting will be accomplished by utilizing battery backup ballast <br /> in the ceiling lighting in combination with the emergency battery lights at the exit <br /> signs. <br /> /d: Maximum occupant load signs should be provided. The signage, location and maximum <br /> occupants should be described on the plans. Section <br /> Response: Maximum occupant load signs have been added to Sheet A1.03 (Room 128) <br /> and Sheet A1.04(Rooms 210 and 211). <br /> The plans should show the means of compliance for electric vehicle charging infrastructure as <br /> required by Section 427 (WA State Amendment). <br /> Response: Five electrical vehicle charging stations have been added to Sheet A0.01 <br /> along the north side of the building. <br /> The wall and soffits within enclosed usable spaces under the stairways should be shown protected <br /> by minimum one-hour fire-resistive construction. Details and listings should be provided. Doors <br /> into the storage spaces need not be rated however. Section 1011.7.3 <br /> Response: Wall Type 02 was shown for the below stair assemblies on Sheet A1.03. <br /> Wall types were shown on Sheet A1.04,and Type 02 indicates 1-hour construction. <br /> Detail 6 has been added to Sheet A3.03 to show 1-hour fire assembly. <br /> Accessibility <br /> Where the combined total water closet compartments and urinals provided in a toilet room is six or <br /> more, at least one of the compartments should be ambulatory accessible, in addition to the <br /> wheelchair accessible compartment. Section 1109.2.2 <br /> Response: The restrooms have been update to reflect the added ambulatory bars on <br /> Sheet A4.03. <br /> co) TAHQMA <br /> DESIGN GROUP <br />