My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W BRIDGEWAYS 2018-04-16
>
Address Records
>
23RD DR W
>
5901
>
BRIDGEWAYS
>
5901 23RD DR W BRIDGEWAYS 2018-04-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2018 10:07:43 AM
Creation date
4/16/2018 10:07:40 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
BRIDGEWAYS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_'‘ Interior Lighting Sui.dnary - Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Bridgeways Date 9/22/2015 <br /> Lighting Alterations,Renovations &Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance.Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. If less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (prior to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Ciross Interior Watts Allowed <br /> room#) Space Type" Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Restroom 0.98 101 99 <br /> Dining area:Bar/lounge/leisure dining 1.31 504 660 <br /> Electrical/mechanical 0.95 63 60 <br /> Atrium* = l ilEnt eg eigvlh <br /> 'f2 i g�e'r mer Exist lhWatts- Mi Qi) iii (iill�,,:������ �' Y : <br /> �X�sti13®1. �htll`1.C( � �� x iti �au�iu�ii� ;���� a°2,r},xwa2a� <br /> LRetail Display Allowance from'LTG INT DISPLAYor <br /> * Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> "" For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/ft.ht., Total 668 819 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description""" Fixtures Fixture Proposed <br /> 2x4'lay in fluorescent fixtures T-8,electronic ballast 6 64 384 <br /> 6"recessed compact fluorescent 2 36 72 <br /> 1x4'surface mounted fluorescent light fixture 1 64 64 <br /> Incandescent light bar 1 120 120 <br /> Retail Display Llghtrn rom LIG-NT DISP �f <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 640 <br /> """Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1. Include ALL proposed lighting fixtures. <br /> 2.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> 3.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices of the transformer.For low voltage track lighting list the transformer rated wattage. <br /> 4.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 5.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br /> 6. If#NA appears in Retail Display cells,information on LTG-INT-DISPLAY is incomplete. <br /> Interior Lighting Power Allowance COMPLIES =R"im <br />
The URL can be used to link to this page
Your browser does not support the video tag.