PUBLIC WORKS E-----Sent vii e-mail <br /> 7 <br /> August 14, 2015 <br /> Mr. Chien Chen <br /> Collins Woerman <br /> 710 Second Ave, Ste. 1400 <br /> Seattle, WA 98104 <br /> Project: TI FOR OFFICES ONLY (PHASE I) -TEAGUE <br /> Owner and Tenant: NICHOLSON MACHINE &TECHNOLOGY and TEAGUE <br /> Job Address: 6000 23RD DR W <br /> Permit: B1507-053 <br /> RE: CORRECTIONS LETTER <br /> Dear Mr. Chen, <br /> In response to the application for permit, the plans have been examined and you are advised that revisions <br /> are necessary before a permit can be issued. Please submit a response letter indicating where each item in the <br /> corrections letter is addressed on the drawings, with two printed sets of drawing revisions (slip-sheeted at the <br /> counter by the applicant). Plan review will resume when the requested information is submitted. All required <br /> submittals must be of sufficient detail and information to ensure that the proposed structures will be <br /> constructed in compliance with all adopted codes, <br /> Geral <br /> 1. Please include the construction type in the code analysis. The original permit for the building was for <br /> construction type VB. <br /> 2. The original area of the building was 60,000 square feet. The area under this permit is indicated as <br /> 63,000 square feet. There have not been permits submitted to increase the floor area. Please clarify. <br /> 3. The occupancy is indicated as F-1 under this permit, where it was originally permitted as F-2. Please <br /> clarify the change of use in the code analysis, and identify the F-1 tenant area as a deferred permit <br /> application. <br /> 4. The site plan (sheet A1.1.C) indicates Pacific Coast Marine but the permit application is for a new <br /> tenant. The site plan submitted under this permit is being reviewed as part of this permit application. <br /> If the intention is to defer the site plan, please include it in the deferred permit submittal. <br /> 5. Please identify all new work or deferred permit work on the drawings. <br /> a. For example, if parking lot lines are being restriped, that extent of that work should be <br /> identified on the drawings *(all new striping should be dimensioned, curb cuts should be <br /> detailed, and the accessible parking sign design, location, and height should be shown on the <br /> drawings). <br /> b. The factory/warehouse revisions should be referenced as a deferred permit. <br /> Construction <br /> `/ 1. New parking spaces and driving aisles should be dimensioned relative to the property line locations. <br /> ✓ 2. Parking should be dimensioned in width and depth to meet Everett Design and Construction Standards. <br />