My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-21 2018-09-21
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-21
>
3003 W CASINO RD BLDG 40-21 2018-09-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 4:21:54 PM
Creation date
4/27/2018 9:07:57 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-21
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MATCHLINE - SEE DWG M456-01 LEGEND <br /> W--- -�- - �- -. - --- - - <br /> ® PIPE MAIN ANCHOR <br /> �\ PIPE GUIDE <br /> EXPANSION JOINT <br /> I <br /> os s PIPE SUPPORT/ANCHOR <br /> —14" HPS <br /> N W/4-1/2" INSULATION PS- SEE �\ <br /> M/581-014 M158 1�-015 <br /> 8 - - - - - <br /> - -10.2 <br /> PIPE <br /> GUIDE GENERAL NOTES <br /> PS-4 1. STRUCTURAL EMBEDS IN TUNNELS OCCUR EVERY <br /> 0 <br /> 8'-0". SEE 2/S577-01 FOR EMBED DETAILS. <br /> I <br /> SEE ENLARGED o N 2. UNLESS OTHERWISE NOTED, FOR 14" HPS, USE <br /> PLAN DWG 1-M451 4-1/2" FIBERGLASS INSULATION IN TUNNEL SECTIONS <br /> FOR MECHANICAL LOW ROOF AND VAULTS. INSTALL METAL COVER IN VAULT <br /> ROOM PIPING LOCATIONS, SEE DRAWING M2B. <br /> BELOW L3. STEAM OPERATING PRESSURE IS 200 PSIG. BOILER <br /> ------ <br /> j I I ,- -�- ) RELIEF PRESSURE IS 255 PSIG. <br /> ---- <br /> i----- -t-- ---- --- -- <br /> PS-3-PIPE <br /> ANCHOR I 4. THE STEAM PIPING AND CONDENSATE PIPING <br /> Z g LAYOUTS ON THIS PROJECT WERE DESIGNED <br /> h i o TO ACCOMMODATE A FUTURE FIRE WATER MAIN <br /> 6 <5 AS LARGE AS 20" DIAMETER, AND FUTURE AIR <br /> 7 SEE WALL �h AND DOMESTIC PIPE AS WELL. THE FUTURE <br /> PENETRATION o,? FIRE WATER MAIN SHOULD OCCUPY THE <br /> DETAIL (SIMILAR �N LOWEST LEVEL OF THE PIPE CHASE WITH A <br /> 491 W/34"O HOLE) 8 BOTTOM OF PIPE NOT TO EXCEED 6"ABOVE <br /> fIFINISHED FLOOR ELEVATION FOR OPTIMUM <br /> M581--06 J� SPACE UTILIZATION. <br /> - i REFERENCE DRAWINGS <br /> j PS-13 <br /> CONSTRUCTION NOTES <br /> (E) 12" <br /> VENT TO O s' -7 - <br /> ATMOSLOCATIONS & ELEVATIONS. <br /> 1. SEE CIVIL DRAWINGS FOR TUNNEL AND VAULT <br /> - - - r 41HPS DbWN <br /> TUNNE <br /> CAPS" TH�U LOI ROOF 2 SLOPE. SEE CIVIL. STEAM PIPINGOPE DRAWINGSLLOW FOR SLOPE• <br /> h <br /> RS. I <br /> 3. SUPPORT 2", 1 1/2" & 1"NPS PIPE (FLASH <br /> VENT, HPC, PC, CA) A MAXIMUM 8'-0" O.C. IN <br /> TUNNELS. REFER TO TUNNEL SECTIONS <br /> I <br /> M581-03, SEE M581-05 FOR SMALL BORE <br /> (E) 2„ I PIPE SUPPORTS TO USE. <br /> VATNT MO$TO - 4. CONDENSATE PIPING SHALL BE INSTALLED WITH <br /> I - -- - A MINIMUM 1" FIBERGLASS INSULATION FOR <br /> PERSONNEL PROTECTION UNLESS OTHERWISE <br /> OUTLINE OF <br /> MECHANICAL NOTED. SEE DRAWING M2B. <br /> I i <br /> ROOM BELOW (E) 10" <br /> TATIRT <br /> 5. PIPE SUPP <br /> I Z VENT TO I 0 S ON NUMBERS DO NOT <br /> ALLOW FOR GAP TOLERANCE IN TUNNEL <br /> LOW ROOF ATMOS SECTIONS. INSTALL SUPPORTS IN MIDDLE OF <br /> !/ THE CLOSEST TUNNEL EMBED. <br /> t ©PROVIDE 6"THICK "FOAMGLASS" INSULATION WITH <br /> - - + - - - 0.4 1 3 5 7 9 11 13 15 ALUMINUM JACKET IN THIS SECTION OF PIPE. <br /> A �MIETER 45-LD VERIFY BOW AT APPROXIMATELY 4' ±. <br /> C ®PROVIDE (2) 300# RF WELD NECK FLANGES. <br /> I- FlM6 E PE:�:,CORE DRILL 20"0 HOLE THROUGH CONCRETE <br /> G ROOF STRUCTURE FOR 14"0 HPS STEAM DOWN. <br /> FIELD VERIFY EXACT LOCATION. PROVIDE ROOF <br /> H FLASHING AND COUNTER FLASHING FOR <br /> IM6 1M6 ---1M6 J PENETRATION. <br /> BUILDING 45-001 OVERALL PIPING PLAN N K 1 >CUT EXISTING BUILDING SANDWICH PANEL FOR <br /> PIPE SUPPORT INSTALLATION AND PROVIDE <br /> SCALE: 1/8"=1'-0" M60-008 IM64 1M6 M APPROPRIATE WEATHER SEAL AND PATCH. <br /> p 1�MITER 45' ELBOW AT APPROXIMATELY 6- t. <br /> FIELD VERIFY. <br /> 100% SUBMITTAL — 05.02.13 COF AN R PROVIDE 14"- 300# RAISED FACE GATE VALVE. <br /> 1601 FNh Avenue,Sofia YDDlsam6e,WA 88101 "DENOTES DRAWING NOT INCLUDED IN THIS SET. <br /> NOT FOR CONSTRUCTION 1TI�'e..e„>n KEY PLAN BLDG. 45-001 <br /> SCALE: NONE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE S0"' CURRENT REVISION DATE _ <br /> _ ORIG SITE—45-001 CONNECTION—STEAM UPGRADES 11578401 CEI/MS MS 05.02.13 C�p4-ASO , ACCEPTABILITY R.CHECLEITNKED <br /> R 05.02.13 115784011""0 _ <br /> Sn, G mis DESIGN AND/OR STEAM UPGRADES ENLARGED PLANSRI 05.02.13 <br /> SPECIFlWON IS APPROVED R.LEITNER 05.02.13 mLESHEET <br /> BOE/A/G® APPRovED Br DEPT DATE ENG <br /> CEI 05.02.13 SITE - 45-001 CONNECTION - STEAM UPGRADES M456-02 <br /> CHECKED <br /> M. VED 05.02.13 SITE 45-YD <br /> 38611 JOB rv0. COMP N0. <br /> 11578401 <br /> 'mAL MECHANICAL MASTER EVERETT, WA 6'G ND. 45-YD-M456-01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.