STATUS LED 4. Refer to publications P/N 06-236120-001 or <br /> An LED is provided on the SmartOne to indicate status of P/N 06-236121-001 for recommended field wiring. <br /> the smoke detector. A high flash rate indicates alarm, a Note: Nominal factory settings of detectors are as fol- <br /> slow rate normal. When a trouble exists, the LED is lows: <br /> turned off. <br /> PROGRAMMING INFORMATION Photoelectric detectors: Alarm 2.0%/ft. <br /> Each detector is field programmed with the owner loca- Pre-alarm 1.5%/ft. <br /> tion message (location of the detector in the building or lonization detectors: Alarm 1.0%/ft. <br /> on the site), the system address (a four digit code), pre- Pre-alarm 0.8%/ft. <br /> alarm set point and alarm set point (if different from fac- Thermal detectors: Alarm 140°F (60°C) <br /> tory settings). In addition, the detector type, either photo- Pre-alarm 120°F(49°C) <br /> electric, ionization or thermal and the proper calibration <br /> are stored in memory at the factory. This permits the The system will reject attempts to program alarm and <br /> Central Control Panel to verify that the proper detector pre-alarm set point levels exceeding the UL designated <br /> type using the correct address is installed in the system. W�ndow. <br /> BASE WIRING INFORMATION ALARM TEST BY COMMAND <br /> Any or all detectors can be tested by command from the <br /> O U O � O Q Central Control Panel. This test procedure precisely <br /> duplicates in-place testing of each detector by imposing a <br /> signal on the detector sensing chamber that will cause an <br /> 7 3 7 3 alarm output. Results of the test will be indicated at the <br /> Central Control Panel or any remote location for monitor- <br /> O O � U ing or troubieshooting purposes. <br /> � � COMMUNICATION VERIFICATION <br /> To wdTx When a detector reaches its pre-alarm or alarm set point, <br /> it conducts a verification procedure with the Central Con- <br /> trol Panel which repeats the communication cycle four <br /> separate times before the system accepts its change of <br /> To prevent detection contamination status. The maximum time for this verification procedure <br /> Aand subsequent warranty cancellation, is 2.5 seconds. <br /> CAUTION smoke detectors must remain covered DETECTOR IDENTIFICATION <br /> until area is clean and dust free. <br /> GENERAL NOTES Part Number Description <br /> 1. No E.O.L. device is needed for SmartOne detectors. 70-400001-100 Common 6-in. Base <br /> 2. T"tapping wiring method is acceptable for Class"B" Model 6S6 <br /> wiring. The number of taps used is a function of <br /> good practice. 70-40001-101 Common 4-in. Base <br /> 3. To ensure proper installation of the detector head to Mode14SB <br /> the base, be sure wires are properly dressed at 70-40001-200 Mechanical Adapter <br /> installation. Model MA-002 <br /> a. Position all wires flat against the base. <br /> b. Take up all slack in outlet box. 70-402001-100 lonization Detector <br /> c. Route wires away from the connector termi- Model CPD 7052 <br /> nals. 71-402001-100 Photoelectric Detector <br /> Model PSD 7152 <br /> 70-404001-100 Thermistor Heat Detector <br /> Model THD 7252 <br /> -2- <br />