My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-37 2018-09-21
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-37
>
3003 W CASINO RD BLDG 40-37 2018-09-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 2:50:05 PM
Creation date
4/27/2018 2:32:37 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-37
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seatronics,inc. Boeing 40-37 Section 1 <br /> Job: 111025 Fire Alarm System Submittal Manual Page 4 <br /> 5. FAULT/TROUBLE CONDITIONS: <br /> 5.1 CONDITIONS IN THE SYSTEM THAT MAY CAUSE FAILURE, OR IMPAIR OPERATION OF THE <br /> SYSTEM SHALL CAUSE THE FOLLOWING: <br /> a. CAUSE THE TROUBLE INDICATOR LAMP ON THE FACP TO ILLUMINATE. <br /> b. CAUSE THE fNTERNAL SOUNDER DEVICE IN THE FACP TO ACTIVATE <br /> c. DISPLAY PROPER MESSAGE ON FACP LCD DISPLAY WITH TROUBLE LOCATION <br /> INFORMATION. <br /> d. DISPLAY TROUBLE POINT LOCATION ON THE REMOTE ANNUNCIATORS <br /> e. TRANSMIT A TROUBLE SIGNAL TO CENTURYLINK'S REMOTE MONITORING STATION. <br /> f. ACTIVATE THE FACP DIGITAL DIALER/COMMUNICATOR AND TRANSMIT A TROUBLE <br /> SIGNAL TO THE CENTRAL STATION MONITORING COMPANY. <br /> THE FOLLOWING IS AN ABBREVIATED LIST OF THE TYPES OF FAULTS THAT WILL CAUSE <br /> A TROUBLE CONDITION TO REPORT TO THE FACP. <br /> a. OPEN, SHORTED OR GROUNDED WIRING ON ANY DETECTION CIRCUIT. <br /> b. OPEN, SHORTED OR GROUNDED WIRING ON ANY MANUAL CIRCUIT. <br /> c. ANY MISSING OR REMOVED ADDRESSABLE DEVICE SUCH AS SMOKE DETECTORS, <br /> POINT MONITORING MODULES OR MANUAL STATIONS. <br /> d. OPEN, SHORTED OR GROUNDED WIRING ON ANY NAC{HORNISTROBE) CIRGUfT. <br /> e. ACTIVATION OF ANY PANEL`BYPASS"OR"OVERRIDE" FUNCTION. <br /> f. CONTROL PANEL STAND-BY BATTERY FAULT. <br /> g. LOSS OF PRIMARY 120 VAC POWER TO PANEL FOR MORE THAN 90 SECONDS. <br /> h. LOSS OF 24VDC POWER. <br /> i. FAILURE OF THE SYSTEM DIALER/COMMUNICATOR TO PROPERLY"CHECK-IN"TO THE <br /> CENTRAL STATION MONITORING COMPANY ONCE EVERY 24 HOURS OR LOSS OF <br /> EITHER OR BOTH PHONE LINES CONNECTED TO THE DIALER. <br /> End <br /> Seatronics, Inc. PO BOX 1138 Auburn, WA 98001 253-939-606� <br />
The URL can be used to link to this page
Your browser does not support the video tag.