My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-92 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
3003 W CASINO RD BLDG 40-92 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 4:17:32 PM
Creation date
4/30/2018 8:22:28 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
............... ......�............. . . ._..... ...... —............................. ... ... .. ............_....__._...__..... . .... <br /> 13. Fire A[arm System-An appraved automatic fire detecti�n system shal] be provided as required by <br /> City�rdinance No.3021-fl7,Chapter 16.76,of the �verett Municipal Cade. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended far use. Appropriate trip <br /> tests,witnessed by a Fire Department Inspector,shall be perfarmed,along with a certificate of <br /> completion, priorto final acceptance ofthe system. - <br /> Fire alarm systems sha11 be instalted according to N�PA Chapter 72,2010 Edition. installatian of fire <br /> alarm components,including basic wirir�g, may not commence before ptans are approved by the <br /> �ire C�epartment Plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient <br /> detail,and must be internally cansistent. Riser diagrams must match installation plans and load <br /> calcufations. Companents�nust be listed and approved for use together, Changes ta plans must <br /> include new drawings and calculations and must be approved by the Fire Department Pfan R�viewer <br /> priar ta instaltation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An appraved set of plans and th� Engineering&Public Services Department electrical <br /> permit must be present for any installation inspection. <br /> Fire alarm systems shalf be installed under permit of the City of fveret# �ngineering&Public <br /> Services Department. Electrical inspections and approval are required prior ta calling far acceptance <br /> tests. Call (425}257-8810 for perrnit infprmation. <br /> The absence af working phone lines for the alarm system will be cause far postponing F�re <br /> Department inspection and testing and shall result in denial of accupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out priar to final occupancy(NFPA 72, <br /> 2010 Edition,Chapter 10, page 114). <br /> Cal[far design requirements per Authority Maving Jurisdictian. <br /> Automatic smoke detection is required. <br /> Both the fire suppression system and the fire alarm system from the existing 40-9Z Building are to <br /> k�e carried through into the new remodel sections. <br /> 14. Fire Suppression{Sprinkler)System-An approved automatic suppression system shall be pravided <br /> as required by City Ordinance No.3021-07,Chapter 1F.76,of the £verett Municipal Code. "fhe <br /> sys#em mus#include a mechanical water gong belE. <br /> Plans far any such system shall be submitteci to the Engirteering&Pu61ic Services Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will supply <br /> the sprinkler systern. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br /> 13, NFPA 13R, ar NFPA 13D system depending upon several factars. Sprinkler installation shall not <br /> begin without an appro�ed and st�mped set of plans from the Engineering&Public Services <br /> Department. The Fire Department wilf also review the plans and shall field inspect the installation <br /> Addendum No.!8 <br /> SEPA1$-032-Boeing Safety Promotion Exhibit Center <br /> ,,.-„�;,,..,.,�� <br /> � <br /> , � . <br />
The URL can be used to link to this page
Your browser does not support the video tag.