My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-12 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-12
>
3003 W CASINO RD BLDG 45-12 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 1:08:21 PM
Creation date
4/30/2018 8:39:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-12
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans ecklist, pg. 1 ENV-CHK <br /> 2012 Washington State Energy Code Compliance orms for Commercial Buildings including R2&R3 over 3 stories and all R1 <br /> Project Address Boeing Everett Facility Date 9/4/2015 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy <br /> Code,Commercial Provisions. <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> SCOPE <br /> na C101.5.2 Low energy spaces Low energy spaces identified on plans <br /> na C101.5.2.1 Semi-heated spaces Semi-heated spaces identified on plans <br /> C402.1.4 <br /> C402.5 Cooler and freezer Walk-in and refrigerated warehouse cooler and freezer spaces identified on <br /> na C402.6 spaces plans <br /> na C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plans <br /> C101.4.4 Change of Existing F,S and U-occupancy building spaces undergoing a change of <br /> na C101.4.5 occupancy/space occupancy or space conditioning that require compliance are identified on <br /> conditioning plans <br /> ENVELOPE PROVISIONS <br /> yes C303.1 Insulation Indicate identification mark shall be applied to all insulation materials <br /> identification A200 <br /> C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor,SHGC,VT,and <br /> na C402.4.3 rating leakage rating <br /> Indicate installation methods,thicknesses,densities and clearances to <br /> C303.1.1 General insulation achieve the intended R-value of all insulation materials; <br /> yes C402.2 installation Where two or more layers of rigid insulation will be used,indicate that edge RFA160-10 thru <br /> joints between layers are staggered RFA160-15 <br /> Indicate R-value(s)of cavity/continuous insulation on roof sections; <br /> Indicate framing materials on roof sections; <br /> Indicate method of framing for ceilings below vented attics and vaulted <br /> yes C402.2.1 Roof assembly ceilings per A102.2(std,adv); <br /> insulation Provide area-weighted calculations for sloped insulation installed entirely <br /> above deck; <br /> Indicate R-values for thermal spacers and each insulation layer,and liner RFA160-10 thru <br /> system(LS)method for metal building roofs RFA160-15 <br /> na C402.2.1 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br /> insulation NFRC rating <br /> Indicate R-value(s)of cavity/continuous insulation on wall sections; <br /> Indicate framing materials on wall sections; <br /> C402.2.3 Indicate method of framing for wood const per A103.2(std,int,adv); <br /> yes C402.2.4 Above/below grade Indicate mass of masonry walls; <br /> wallin <br /> C303.2.1 `Nall insulation <br /> Indicate loose-fill core insulation material,percentage of cores filled,and <br /> frequency of grouted cores and bond beams for masonry walls; <br /> Indicate method of protection of exposed exterior basement/crawlspace wall <br /> insulation A200 and A500 <br /> Walk-in/refrigerated Indicate insulation R-values of ceilings,walls,doors,floors on sections; <br /> na C402.5 warehouse cooler Indicate method of minimizing door infiltration; <br /> C402.6 and freezer <br /> insulation Indicate type(s)of transparent doors and windows <br /> yes C402.2.7 Opaque doors Indicate rated U-factor(swinging)or R-value(roll-up/sliding)on wall sections- <br /> applies to doors with less than 50%glazed area A500 <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> na C402.2.5 unconditioned space Indicate framing material on floor sections; <br /> insulation Indicate mass of masonry floors <br /> Indicate R-value of continuous insulation on wall section or foundation detail; <br /> C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required <br /> yes C303.2.1 insulation <br /> distance from top of slab; <br /> Indicate method of protection of exposed exterior slab edge insulation A200 and A500 <br /> Indicate R-value of continuous insulation on wall section or foundation detail; <br /> C402.2.6 Radiantly heated Indicate insulation extends down vertically from top of slab and then <br /> na slab-on-grade floor <br /> C303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> na C402.2.8 bottom surface of radiantly heated floors(other than radiantly heated slab-on- <br /> system insulation grade) <br /> (1& <br />
The URL can be used to link to this page
Your browser does not support the video tag.