Laserfiche WebLink
, r <br /> CITY OF EVERETI PER/1�i COMMENT RESPONSES <br /> DR, EGGENBERGER T,l, —EVERETI, WA <br /> 07/21/2017 <br /> Page 2 <br /> of parking stalls provided. If there are 26 stalls, two van <br /> accessible stalls are required. <br /> b. The van accessible stall should be shown as being 16 feet wide, <br /> per ICC-A117.1-2009 section 502.2, with a minimum access aisle <br /> width of 5 feet, per ICC-A117.1-2009 section 502.4.2. <br /> c. The location of the accessible parking should be on the shortest <br /> route to the primary accessible building entrance, per IBC section <br /> 1106.6 and IEBC Section 1105.1. <br /> d. Please document the accessible route to the primary entrance <br /> door, per ICC-A117.1-2009 section 403.4 to include conforming <br /> curb cuts, if used,and accessible door hardware on the drawings. <br /> e. The width of the exterior accessible route should be shown to be <br /> 44 inches, per IBC section 1102.1, as amended by the State of <br /> Washington. <br /> f. Accessible parking signage should indicate compliance with <br /> height and content of signage per ICC/ANSI A 117.1-2009 <br /> section 502.7. <br /> RESPONSE: <br /> Per your request a site plan addressing all items specified has been added; sheet A2.00. <br /> 3) Energy <br /> 1. Please include actual code section language of the drawings for interior and <br /> exterior lighting controls, sensors, and all other methods of compliance covered in <br /> electrical power and lighting systems per WSEC section C405. <br /> RESPONSE: <br /> Per your request this language has been added and clouded on sheet A7.00 under General <br /> Daylight Zone notes. <br /> Thank you, <br /> �RITTl4NY BRUWN <br /> SENIOR INTERIQR DESIGNER <br /> � ���,:��:�1 Tr.L � $�*�a a'�s',�' �".✓Y�a Rq :��34� � '�,,,,I.. <br /> ��_425 827 2100 ��:425 828 6899 `�=: atri fhoarch.cam <br /> ,� <br /> a � <br />