My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SRV Construction Company 5/1/2018
>
Contracts
>
Capital Contract
>
SRV Construction Company 5/1/2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2020 12:24:08 PM
Creation date
5/3/2018 9:23:14 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
SRV Construction Company
Approval Date
5/1/2018
Council Approval Date
4/11/2018
Department
Public Works
Department Project Manager
Richard Hefti
Subject / Project Title
Water Main Replacement Q Evergreen Way
Public Works WO Number
UP3612
Tracking Number
0001180
Total Compensation
$1,450,524.96
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
SRV CONSTRUCTION 4/11/2019 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
SRV Construction 4/16/2020 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> not less than 25 mg/I. Contractor may reduce disinfectant chlorine solution contact <br /> time from 24 to 12 hours by using an initial disinfectant concentration of 50 mg/I. <br /> Maximum allowable disinfectant concentration shall be 50 mg/I. The ending <br /> concentration of an initial 50 mg/I solution following a 12 hour contact time shall be <br /> not less than 10 mg/I. <br /> ' 7-09.3(24)C Form of Applied Chlorine <br /> Perform disinfection of water mains using the continuous feed method employing <br /> either liquid calcium hypochlorite or liquid sodium hypochlorite solutions. Dry <br /> calcium hypochlorite and gaseous or liquid chlorine is not allowed. <br /> Follow the continuous feed methods specified in the most recent version ofAWWA <br /> Standard C-651 and Section 5-15 of the latest edition of the City of Everett <br /> "Design and Construction Standards and Specifications for Development", except <br /> for the City's prohibition on the use of dry calcium hypochlorite or gaseous <br /> chlorine. <br /> 7-09.3(24)D Point of Application <br /> Whenever possible, use the beginning of the pipeline extension, or a valved <br /> section of it, as the point of application for the disinfectant solution. Provide a tap <br /> to supply water for delivering the disinfectant solution on the pressure, or <br /> upstream, side of the valve controlling the flow into the pipeline extension, but <br /> downstream of the backflow preventer used to isolate the new main from the <br /> existing water distribution system. Obtain Engineer approval in writing to use <br /> alternate points of applications. <br /> For a City allowed direct tie-in to an existing main via an in-line backflow preventer <br /> and with the approval of the Inspector, the point of application may be through a <br /> corporation stop inserted in the horizontal axis of the pipe. Locate tap within 10- <br /> feet of where the line is tied into the existing system. Swab the internal surfaces <br /> of the backflow preventer and adjacent downstream appurtenances, valves or <br /> couplings for example, with straight hypochlorite solution prior to their installation. <br /> 7-09.3(24)E Preventing Reverse Flow <br /> Provide a State Department of Health approved backflow preventer installed in the <br /> ' connecting line before making a connection between the existing distribution <br /> system and water lines constructed under this Contract that have not been <br /> flushed, disinfected, and tested. Install backflow preventer upstream of temporary <br /> fill hoses and disinfectant injection equipment. <br /> 7-09.3(24)F Chlorinating Valves, Hydrants, and Appurtenances <br /> Operate valves, hydrants, and other appurtenances during the disinfectant contact <br /> interval for newly-laid pipe while filling the pipeline with the disinfectant chlorine <br /> solution and the main is under normal operating pressure. Normal operating <br /> pressure is the pressure the existing distribution system provides through the <br /> temporary backflow protection device. <br /> 7-09.3(24)G Chlorinating Connections to Existing Water Mains and Water <br /> Service Connections <br /> Chlorinate connections to existing water mains in accordance with the following <br /> sections of the most recent revision of AWWA Standard C651: <br /> Section 4.6 - Final Connections to Existing Mains, <br /> ' Section 4.7 - Disinfectant Procedures When Cutting Into or Repairing Existing <br /> Mains, and <br /> Section 4.8 - Special Procedures for Caulked Tapping Tees <br /> Water Main Replacement"Q" Division 7-STORM, SEWER,WATER February 9, 2018 <br /> -Evergreen Way Rebid <br /> WO No.-UP3612 SP-155 <br />
The URL can be used to link to this page
Your browser does not support the video tag.