1 Nil — M r M M MD M 41110t all 0111 N- 1N — e a — no <br /> I I <br /> SEE STANDARD DRAWING 808 PAVED SHOULDER TRAVELLED WAY GENERAL NOTES FOR LOOP INSTALLATION: <br /> FOR JUNCTION BOX INSTALLATION - <br /> OR SIDEWALK AREA SEE DETAIL A 1. INSTALL JUNCTION BOX AND LEAD-IN CONDUIT. <br /> SEE SPLICE DETAIL THIS SHEET <br /> THIS SHEET 2. SAW LOOP SLOTS AND LEAD-IN SLOTS. <br /> 3. LAY OUT LOOP WIRE BEGINNING ATJUNCTION BOX,ALLOWING 5'MINIMUM SLACK. <br /> SEE NOTE 11 r�.‘tm�r / 4. INSTALL WIRE IN LOOP SLOT.SEE LOOP WINDING DETAIL. <br /> 7 5. RETURN TO JUNCTION BOX AND IDENTIFY LEADS WITH PLAN DETECTOR NUMBER AND <br /> ` ' 'o PAVED SHOLDER "5"FOR START AND"F"FOR FINISH. <br /> t " 6. TWIST EACH PAIR OF LEAD-IN WIRES TWO TURNS PER FOOT FROM LOOP TO JUNCTION <br /> SEE PLANS FOR <br /> IF_ <br /> z <br /> CONDUIT SIZE 1` ,, r4 4 BOX AND INSTALL IN LEAD-IN SLOT AND CONDUIT.REVERSE DIRECTION OF TWIST FOR <br /> 1 ', �- = SEE DETAIL A EACH SUCCESSIVE PAIR INSTALLED. <br /> 43 ]-' THIS SHEET <br /> 7 CONSTRUCT SUPPLEMENTAL SPLICE CONTAINING ANY SERIES OR PARALLEL LOOP <br /> `u CONNECTIONS REQUIRED IN PLANS.SUPPLEMENTAL SPLICES ARE SUBJECT TO THE <br /> / SAME REQUIREMENTS SHOWN FOR THE LOOP LEAD AND SHIELDED CABLE SPLICE.IF <br /> 6"DEEP <br /> / APPROVED BY ENGINEER SCOTCHLOK 3570 EPDXY KIT SEALING PACKS MAY BE <br /> GRAVEL BASE SUBSTITUTED FOR THE SCOTCHCAST 82-B1 FOR SUPPLEMENTAL SPLICES. <br /> SEE TABLE A <br /> FOR CONDUIT SIZE 8. SPLICE LOOP LEADS OR SUPPLEMENTAL SPLICE LEADS TO SHIELDED CABLE AS NOTED. <br /> 9. COMPLETE INSTALLATION AND TEST LOOP CIRCUITS OR COMBINATION LOOP CIRCUITS. <br /> JUNCTION BOX GURB &GUTTER SEE WSDOT STANDARD SPEC 8-20.3(14)D. <br /> 10. FOR LOOP LOCATION REFER TO STANDARD DRAWING 805 AND PLANS. <br /> TYPICAL CONDUIT PLACEMENT FOR LOOP LEAD-IN WIRES 11. SEAL ENDS OF CONDUIT WITH ELECTRICAL PUTTY OF SILICONE. <br /> 12. DRILL HOLE FOR HOME-RUN CONDUIT 1"LARGER THAN CONDUIT AND FILL VOID WITH <br /> HOT MIX ASPHALT. <br /> LOOP LEAD PAIRS 1-2 3 4-5 6-8 9-12 13. ALL SPLICES SHALL BE ABLE TO BE RAISED A MINIMUM OF 16"ABOVE GROUND LINE. <br /> CONDUIT SIZE(MIN) 2" 2" 2" (2)2" (2)2" 14. BUCHANAN 2006S SPLICE CAPS,CRIMP WITH BUCHANAN C-24 CRIMPER FOLLOWING <br /> TRENCH WIDTH(MIN) 4" 4" 4" 6" 6" MANUFACTURE'S INSTALLATION PROCEDURE.SOLDER CRIMP(NO OPEN FLAME TORCH <br /> NOTE:ALL STOP BAR LOCATIONS SHALL HAVE(2)2"CONDUIT SIZE MINIMUM OR SIMILAR IS ALLOWED)AND TAPE WITH 2 LAYERS OF TAPE. <br /> TABLE A ®INSTALLATION NOTES: <br /> 1. SEALANT-CRAFCO PART NO 34271,OR APPROVED EQUAL. <br /> 2. LOOP WIRE-NUMBER VARIES SEE LOOP WINDING DETAILS STANDARD DRAWING 810. <br /> XDETECTOR LEAD-IN CABLE FOIL SHIELD 3. LEAD-IN WIRES:ONE PAIR FOR EACH LOOP SERVED,3 PAIR MAX PER SAWCUT. <br /> $ (IMSA 50-2-1984)OR 3 <br /> 8 SHIELDED PAIR CABLE 4. EXTEND SAWCUT SUFFICIENT LENGTH TO PROVIDE FULL SAWCUT DEPTH AROUND <br /> (BELDEN 1037A)AS NOTED 1 1/2" 1" SEE NOTE 14 CORNERS. <br /> 8 NMIEDGE OF TRAVELLED WAY <br /> / 11.111,1". ". .' 1 SEAL ENDS WITH OR CURB/GUTTER 5. LOCATE CORNER SAWCUT AT 45'TO SIDE CUTS TO PREVENT KINK IN LOOP WIRE AND <br /> _'_�wA -�- I/ ELECTRICAL PUTTY A ALSO MINIMIZE VOID.TRIANGULAR VOID WILL BE REMOVED AND FILLED WITH <br /> 9 AND TAPE 6" SEALANT. <br /> LOOP WIRE#14 `DRAIN WIREV OD A <br /> fil (IMSA 51-7) 4411i <br /> F / *GROUND DRAIN WIRE AT SCOTCHAST EPDXY <br /> 6 � FILLS AMPLIFIER ONLY SPLICE KIT SEE NOTE 12 (TYP) <br /> CITY OF EVERETT <br /> 8 FILLED WITH EPDXY SAWCUT TYP <br /> i o F USE SAME PROCEDURE FOR 3 PAIR LEAD-IN <br /> Wn S CABLE AND MULTIPLE LOOP SPLICE ETT PUBLIC WORKS DEPARTMENT <br /> SPLICE DETAIL DETAIL A <br /> ''"RYAN SASS !MEV HEM' 1 IAUL WILHELM I SH 04/07/2017 <br /> 0sK TRAFFIC INDUCTION LOOP 809 <br /> ,' JUNCTION BOX,SPLICE&NOTES <br /> I <br />