|
MATCHLINE - SEE DWG 45-YD-C150-03
<br /> �-' -- -- - -- ❑ -- -- ! -- - -- -- - - - - -- - j � � -� -- -- �EG EN D
<br /> � x
<br /> 45-297 45-205 IE- OWN � 1
<br /> x I
<br /> I � � � � � � ` _ — � . ❑ � � Q INDICATES PANEL TO BE REPLACED
<br /> I � � • • � I
<br /> i ) .
<br /> � � ELEVATION AT CORNER OF PANEL
<br /> �.. ' SS 0 � � � � LIMITS OF P.C.C. PAVEMENT WORK
<br /> � � � y y N � * P.C.C. = PORTLAND CEMENT CONCRETE
<br /> � �" � ' 1
<br /> ss��9 Ss�s �y��, y�������39 � � ,...,• I
<br /> � � � ' I
<br /> I � � �y�6,�ya, y2°` ���3 �- � �
<br /> � 3 • . �.;�, .
<br /> 1 I 5�g y2� �ya1 y�.� �ti� yy�,. I
<br /> . ., �:.. :.�.'; ::
<br /> 1 � � ! . .
<br /> � f �r.
<br /> � i I . . �
<br /> � � - 11 �
<br /> � . @ r �
<br /> i . . � E ��
<br /> e a � +� 3�' rjt S,j► � � � � � . �
<br /> X , r o 6 I ,, 4� ?i I .. ,�..
<br /> � � 45-235
<br /> 45-719 0 : : GENERA� NOTES
<br /> I � 40' �' �A �°AN
<br /> ' � � -- .-�. 4 I �5-526 � � I 1 . PROTECT ALL EXISTING SURFACE FEATURES TO
<br /> � �' � J 45 9 REMAIN, INCLUDING BUT NOT LIMITED TO STRIPING,
<br /> � � . I
<br /> i VALVE BOXES, FIRE HYDRANTS AND SPRAY NOZZLES,
<br /> �- I 5-Z HAND HOLES, LIGHT POLES, MANHOLES/INLETS,
<br /> I I I UTILITY BOXES, TIE DOWNS, AND EQUIPMENT PRIOR
<br /> � x I o � TO WORK.
<br /> I I
<br /> 1 � N
<br /> x , I � I 2. CONTRACTOR SHALL RAISE ALL SURFACE FEATURES
<br /> I
<br /> � � . I � (EG. MANHOLES, VAULTS, CLEANOUTS, ETC.) TO NEW
<br /> a �'�-210 4��2 7 I PAVEMENT GRADES.
<br /> I
<br /> � � ._._ � � � � � I . 6 � �
<br /> X , � � � f I g5`�$ - 536� 3. EXISTING UNDERGROUND UTILITY FEATURES SHOWN
<br /> , I e � ° 3�3 I ON PLANS AND PROFILES ARE BASED ON SURVEY
<br /> I � �y DATA, GPR SURVEY, AND RECORD DRAWINGS AND
<br /> x ( S .o? ��K--� y '` � � � ARE THE BEST AVAILABLE INFORMATION AT THE TIME
<br /> � I �2 �� ��3g yy��$ � � OF PLANS PRODUCTION. THE CONTRACTOR SHALL
<br /> FIELD LOCATE ALL UTILITIES PRIOR TO THE START OF
<br /> o � � �? �� y°'° 539 5`�$ — x � DEMOLITION WORK.
<br /> � 1 I � y � . � o
<br /> � � i � � y53� � . �n
<br /> c� x ! s� s�. �, sF , � c� 4. SEE SHEET C2 FOR GENERAL NOTES.
<br /> o � � �`�° �`'° �'� �°`� �o
<br /> � �
<br /> � � ° � � I E ��
<br /> � ' � !
<br /> ; x , � . � ' � -74. ; CONSTRUCTI0 �1 I� OTES
<br /> � � e e � • FIRE �
<br /> � x + DEP � � � 1 MATCH GRADE AT EXISTING CONCRETE PANELS
<br /> w � � ' �'
<br /> � o �Ioo� �
<br /> � � , —2 3 3 45-257 ,
<br /> w ,� � � c� • I ° ,� w
<br /> Z � � w � z
<br /> = I `e• � •` • DEP ( [� � _ �
<br /> � X � � � � �5-900 �
<br /> Q � � 1. FIP.E FIRE RRE Q
<br /> � ' � � FIRE r OEPT pEPT DEPT r I 6 .
<br /> � � DEPT ¢/
<br /> � 1 �(�, FIRE � I / I
<br /> ' � � GJyO �� �� �� �`T� DEPT �
<br /> � FIRE I
<br /> 1 I SS7 �J�j����7.9 �`J_$ �RE I �
<br /> � I � ( ') DEPT
<br /> ^ I I . �J�yO �8 DEPT I
<br /> � i
<br /> I �! x � � — i y�� ����6 � . �t� D PT ' I
<br /> � I x 45 275 �� 209 A ^ �__�.�s � �
<br /> � � �� � .o, I
<br /> � _ — _ _ — _ � _ 4 I � E
<br /> X I . .
<br /> � I � l � �
<br /> � � FIRE I
<br /> X I / DEPT �
<br /> ' � FIRE
<br /> � I � // DEPT
<br /> X � 1 FIRE
<br /> DEPT
<br /> / FIRE
<br /> I DEPT
<br /> FIRE
<br /> I � �„ DEPT I
<br /> � I � o f cOo o ,� �
<br /> X ' �Q�O o a � o0 0�
<br /> ' , o � / o � °
<br /> • . I � �` � '� 02 � �'03 ' ' 04 05
<br /> . I � / � � .. � 1
<br /> . , m � ❑
<br /> , X . � d � ` � , � °
<br /> � ° 45-23 / � W� � � 06 07� -� 08 09
<br /> x ' � � � �s `� .e
<br /> � 3f E� �TRY � � ..�` �� 1 m 11 � I� 1 13 14
<br /> srua sraR sraR � O 2
<br /> APo�NG ARI(ING ARKIN�
<br /> � �Y ONLY ONLY �/ Q � Q�
<br /> �E � /�o �y m
<br /> � x � �..o � � s � � — — — � � -� p� .� �. .x � 15 �a 16 17 18 /19
<br /> ,�* ���QQQ� �
<br /> � x� ,�+c � .x s�, �
<br /> x 1 �� � ----- � � 20 � 21 � 22 � 23 24� 25
<br /> I � _
<br /> � X � � � � i 2 6, 2 7 2 8
<br /> ' � �5-29� 45-211
<br /> a � 29'4 30'�
<br /> ; _ � � � -
<br /> X — � — ` — -- ` -- -- -- — � -- -- -- �—� -- -- -- -- --
<br /> -- -- K EY P LAN � I
<br /> MATCHLINE — SEE DWG 45—YQ—C150-11 O��AN � v
<br /> 9�% S U B M I TTAL SCALE: NONE
<br /> N G I N E E R S 40 20 0 20 40 80 =
<br /> PA R T I A L P �A N 1601 Fifth Avenue,Suite 900� Seattle,WA 98101 �
<br /> . „ , N ph 206.623.0717�fax 206.624.3775 I S S U E D F 4 R P E R M I T �
<br /> SCALE. 1 = 40 coffman.com :
<br /> LASTWG crea�ivily�resutls�rela�ionships S C A L E: 1 :4 0 �
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ��1 L. ACCEPTABILITY C. PEARSON GRADING PLAN W4535737 E O�J.O9.�7 �
<br /> A FLIGHTLINE-STALL 120 RENOVATIONS 10671066 TT-JMM 10-01-10 E 777X STALL MODIFICATIONS - PHASE 2 W4535737 CEI AH 05.09.17 ti�w oF WAsr�I THIS DESIGN AND/OR `
<br /> y � . -, SPECIFlCATI4N IS APPROVED SHEEf
<br /> B CONCREfE PANEL REPLACEMENT RL BO 05.09.12 BOE,��� Q �� � APPROVED BY DEPT. DATE � 777X STALL MODIFICATIONS - PHASE 2 � �
<br /> CHECKED C 15� 0 7 `
<br /> C FIRE MAIN RELOCATION � RECORD C1946 DOWL HKM TLB 05.14.13 SITE 45 YD
<br /> � JOB N0. COMP N0.
<br /> - NEDC - RECORD DRAWING 11347705 DLR GRP 10.25.13 � ,��GasSaT�R�� ��;4 A v '
<br /> D FIRE STATION IMPROVEMENT W436743 MKA 08.22.14 �S'szo�,TaLE��I A � CIVIL MASTER EVERETT, WA °Wc No. 45—YD—C150-07
<br /> 5/9/2017 (PAPFR SPA(:Fl .�',FF� 4.�i—Y!
<br />
|