Laserfiche WebLink
r <br /> Chapter 6. Plumbing Elements and Facilities ICC A117.1-2009 <br /> i � <br /> I <br /> 608.2.'9.1 Size. Transfer-type shower compart- � <br /> ments shall have a clear inside dimension of 36 I <br /> inches (915 mm) in width and 36 inches (915 mm) � <br /> in depth, measured at the center point of opposing � <br /> sides. An entry 36 inches (915 mm) minimum in <br /> width shall be provided. <br /> � end 608.2.1.2 Clearance. A clearance of 48 inches 1 <br /> Wall (1220 mm) minimum in length measured perpen- <br /> dicular from the control wall, and 36 inches (915 <br /> � mm) minimum in depth shall be provided adjacent , <br /> to the open face of the compartment. <br /> 608.2.1.3 Seat. A folding or non-folding seat com- <br /> plying with Section 610 shall be provided on the <br /> , ' wall opposite the control wall. <br /> Exception: A seat is not required to be <br /> installed in a shower for a single occupant, <br /> accessed only through a private office and not <br /> for common use or public use, provided rein- <br /> FIG.607.5 forcement has been installed in walls and <br /> LOCATIOM O�B�.YIiTUB CONTROLS located so as to permit the installation of a <br /> shower seat. <br /> 607'.8 Water 1'ernperature. Bathtubs shall deliver water <br /> that is 120°F (49°C) maximum. 608.2.2 Standard RolB-in-type Shower Compart- <br /> rnents. Standard roll-in-type shower compartments <br /> 60�Sh�wrer C�mpartrnents shall comply with Section 608.2.2. <br /> 60�.1 Geraeral. Accessible shower compartments shall 608.2.2.1 Size. Standard roll-in-type shower com- <br /> comply with Section 608. partments shall have a clear inside dimension of <br /> 60 inches (1525 mm) minimum in width and 30 <br /> 60�.2 Size, clearance and seat. Shower compart- inches (760 mm) minimum in depth, measured at <br /> ments shall have sizes, clearances and seats comply- the center point of opposing sides. An entry 60 <br /> ing with Section 608.2. inches (1525 mm) minimum in width shall be pro- <br /> 608.2.1 Transfer-type Shower Compartments. vided. <br /> ' Transfer-type shower compartments shall comply 608.2.2.2 Clearance. A clearance of 60 inches 1 <br /> with Section 608.2.1. (1525 mm) minimum in length adjacent to the 60- <br /> inch (1525 mm) width of the open face of the <br /> 36 shower compartment, and 30 inches (760 mm) <br /> 915 minimum in depth, shall be provided. <br /> back wall <br /> � EXCEPTION: A lavatory complying with Sec- 1 <br /> tion 606 shall be permitted at the end of the <br /> clearance opposite the seat. <br /> � 608.2.2.3 Seat. A folding seat complying with Sec- <br /> seat � _ _ �control � � tion 610 shall be provided on an end wall. <br /> wall wall `r' °' EXCEPTIONS: <br /> 1. A seat is not required to be installed in a <br /> �-----------� shower for a single occupant accessed <br /> i i i � only through a private office and not for <br /> i i �� � common use or public use, provided <br /> i � � i � �, reinforcement has been installed in walls <br /> i i "' and located so as to permit the installa- <br /> � � tion of a shower seat. <br /> i i <br /> � 48 min � 2. A fixed seat shall be permitted where the <br /> 122� seat does not overlap the minimum clear <br /> inside dimension required by Section <br /> Note: inside finished dimensions measured 608.2.2.1. <br /> at the center points of opposing sides <br /> 608.2.3 Alternate Roll-in-type Shower Compart- <br /> FIG.6082.1 ments. Alternate roll-in-type shower compartments ' <br /> TRAMSFER-TYPE SHOWER shall comply with Section 608.2.3. <br /> COMPARTMENT SIZE AND CLEARANCE <br /> !�� �l <br /> 56 <br />