j � ICC A117.1-2009 Chapter 6. Plumbing Elements and Facilities <br /> � ' . <br /> � 608.2.3.1 Size. Alternate roll-in shower compart- 608.3.1 Transfer-Type Showers. Grab bars for <br /> ments shall have a clear inside dimension of 60 transfer type showers shall comply with Section <br /> j inches (1525 mm) minimum in width, and 36 608.3.1. <br /> � inches (915 mm) in depth, measured at the center 18 <br /> point of opposing sides. An entry 36 inches (915) <br /> mm) minimum in width shall be provided at one back wall 455 <br /> end of the 60-inch (1525 mm) width of the com- <br /> partment. A seat wall, 24 inches (610 mm) mini- <br /> � mum and 36 inches (915 mm) maximum in length, <br /> �' shall be provided on the entry side of the compart- <br /> ment. seat control <br /> 608.2.3.2 Seat. A folding seat complying with Sec- Wall Wall <br /> tion 610 shall be provided on the seat wall oppo- <br /> site the back wall. <br /> EXCEPTBON: A seat is not required to be <br /> installed in a shower for a single occupant, <br /> accessed only through a private office and not <br /> for common use or public use, provided rein- 4 171aX <br /> forcement has been installed in walls and �02 <br /> located so as to permit the installation of a <br /> shower seat. FiG.sos.s.1 <br /> GRAB BARS IN TRANSFER-71(PE SHOWERS <br /> 608.3 Grab �ars. Grab bars shall comply with Section <br /> 609 and shall be provided in accordance with Section 608.3.1.1 Horizontal Grab �ars. Horizontal grab <br /> 608.3. Where multiple grab bars are used, required hor- bars shall be provided across the control wall and <br /> i izontal grab bars shall be instalted at the same height on the back wall to a point 18 inches (455 mm) <br /> above the floor. from the control wall. <br /> EXCEPTDON: Grab bars are not required to be 608.3.1.2 Vertical Grab �ar. A vertical grab bar <br /> installed in a shower for a single occupant, accessed 18 inches (455 mm) minimum in length shall be <br /> only through a private office and not for common use provided on the control end wall 3 inches (75 mm) <br /> or public use, provided reinforcement has been minimum and 6 inches (150 mm) maximum above <br /> installed in walls and located so as to permit the the horizontal grab bar, and 4 inches (100 mm) <br /> installation of grab bars complying with Section maximum inward from the front edge of the <br /> 608.3. shower. <br /> � � <br /> � back wall � <br /> � side ' � � side ' <br /> wall I wall c I <br /> - —� J�_� � "� o <br /> � � <br /> ti <br /> I � � -- -- � � � <br /> I _� ' rn <br /> ` � side <br /> end <br /> r----------------i � � wall <br /> _ wall <br /> i <br /> i� i �� � <br /> i� , i o �° seat wall <br /> i � i `'' 24–36 36 min <br /> � 610–915 915 <br /> �------------------� <br /> 60 min <br /> � 60 min 1525 <br /> 1525 <br /> Note: inside finished dimensions measured Note: inside finished dimensions measured <br /> at the center points of opposing sides at the center points of opposing sides <br /> FIG.608.2.2 F'IG.608.2.3 <br /> STAYVDARD ROL.�.-B�9-YY��SFiOWER ALTERi�R.TE ROLL-9N-TYPE SEiOWER ; � j g <br /> ��WJPAR�9ViE4VT SEZ�AfV�CLEARA9VCE COMP.4RTVIIiENT S9ZE AND C�EARANCE '\ � . A / , <br /> 57 <br />