Laserfiche WebLink
r <br /> Chapter 6. Piumbing Elements and Facilities ICC A117.1-2009 <br /> , i <br /> 6��.3.2 Stae�darcl Rol9�in-Type SB�or�r�rs. In stan- 60�.4.� Transf�r�3'y�� ��aovv��°�. In transfer-type <br /> dard roll-in type showers, a grab bar shall be pro- showers, the controls and hand shower shall be ' <br /> vided on the back wall beginning at the edge of the located: <br /> seat. The grab bars shall not be provided above the 1. On the control wall opposite the seat_ <br /> seat. The back wall.grab bar shall extend the length ' <br /> of the wall but shall not be required to exceed 48 2. At a height of 38 inches (965 mm) minimum <br /> inches (1220 mm) in length. Where a side wall is pro- and 48 inches (1220 mm) maximum above the <br /> vided opposite the seat within 72 inches (1830 mm) shower floor, and <br /> of the seat wall, a grab bar shall be provided on the 3. 15 inches (380 mm) maximum, from the cen- <br /> side wall opposite the seat. The side wall grab bar terline of the control wall toward the shower <br /> shall extend the length of the wall but shall not be opening. <br /> required to exceed 30 inches (760 mm) in length. <br /> Grab bars shall be 6 inches (150 mm) maximum from � <br /> the adjacent walL <br /> 6 max 15 max � <br /> 150 � 380 , <br /> I <br /> back wall � <br /> x I I control� E N <br /> � o end � end <br /> wall � oo .- <br /> � � wall � I wall �� � `� <br /> � � � <br /> —J ' � i <br /> With Seat , <br /> FIG.608.3.2 FIG.608.4.1 , <br /> GRAB BARS IN STANDARD ROLL-IN-TYPE SHOWERS TRANSFER-TYPE SHOWER <br /> CONTROLS AND HAIVDSHOWER LOCATION <br /> 608.3.3 Alternafe Roll-in-Type Showers. In alternate 608.4.2 5tandard Roll-iro Shovuers. In standard roll- <br /> roll-in type showers, grab bars shall be provided on the in showers, the controls and hand shower shall be <br /> back wall and the end wall adjacent to the seat. Grab located on the back wall above the grab bar, 48 ' ' <br /> bars shall not be provided above the seat. Grab bars inches (1220 mm) maximum above the shower floor ' <br /> shall be 6 inches (150 mm) maximum from the adjacent and 16 inches (405 mm) minimum and 27 inches � il <br /> wall. (685 mm) maximum from the end wall behind the <br /> seat. ! <br /> 6 max 6 max <br /> 150 150 27 max <br /> back wall 6s5 <br /> 16 min <br /> 405 <br /> � � end side back wall \\\\\\\ <br /> � ���I - wall �` <br /> � <br /> � cxa o <br /> -Q � N <br /> _ m N <br /> � � � <br /> N � <br /> seat wall ' <br /> 0 <br /> � <br /> ¢ <br /> FIG.608.3.3 <br /> GRAB BARS IN ALTERNATE ROLL-IN-TYPE SPiOWERS <br /> '� With Seat <br /> 608.4 Controls and Hand Showers. Controls and <br /> hand showers shall comply with Sections 608.4 and FIG.608.4.2 <br /> 309.4. STANDARD ROLL-IM-TYPE SHOWER <br /> CONTROL AND FiANDSHOWER LOCATION <br /> 58 ��� � � <br /> � <br />