My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
>
Address Records
>
EVERGREEN WAY
>
4921
>
TROPICAL TAN
>
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2018 8:23:42 AM
Creation date
5/15/2018 8:23:38 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4921
Tenant Name
TROPICAL TAN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� -- ._ __ _ _ -__� Guide Specification for Page:10 <br /> York Sunline <br /> REFRIGERANT COMPONENTS f. Unit shall incorporate"AUTO RESET"compressor <br /> Compressors: over temperature, over current protection. <br /> a. Shall be internally protected with internal high- g. Unit shall operate with conventional thermostat <br /> pressure relief and over temperature protection. designs and have a low voltage terminal strip for <br /> b. Shall have internal spring isolation and sound easy hook-up. <br /> muffling to minimize vibration and noise, and be h. Unit control board shall have on-board diagnostics <br /> externally isolated on a dedicated, independent and fault code display. <br /> mounting. i. Standard controls shall include anti-short cycle and <br /> Coils: low voltage protection, and permit cooling operation <br /> down to 0 F. <br /> a. Evaporator coils shall have aluminum plate fins j. Control board shall monitor each refrigerant safety <br /> mechanically bonded to seamless internally switch independently. <br /> enhanced copper tubes with all joints brazed. Special k. Control board shall retain last 5 fault codes in non <br /> Phenolic coating shall be available as a factory volatile memory which will not be lost in the event of a <br /> option. power loss. <br /> b. Evaporator coils shall be of the direct expansion, <br /> draw-thru design. GAS HEATING SECTION <br /> c. Condenser coils shall have aluminum plate fins Shall be designed with induced draft combustion with <br /> mechanically bonded to seamless internally post purge logic, energy saving direct spark ignition, and <br /> enhanced copper tubes with all joints brazed or redundant main gas valve.Venter wheel shall be <br /> Micro-Channel aluminum tube, aluminum fins. constructed of stainless steel for corrosion resistance. <br /> d. Condenser coils shall be of the direct expansion, The heat exchanger shall be of the tubular type, <br /> draw-thru design. constructed of T1-40 aluminized steel for corrosion <br /> resistance and allowing minimum mixed air entering <br /> Refriqerant Circuit and Refriqerant Safetv Components temperature of 25°F. Burners shall be of the inshot type, <br /> shall include: constructed of aluminum coated steel and contain air <br /> mixture adjustments.All gas piping shall enterthe unit <br /> a. Independent fixed-orifice or thermally operated cabinet at a single location through either the side or <br /> expansion devices. curb without any field modifications. Integrated control <br /> b. Filter drier/strainer to eliminate any moisture or boards shall provide timed control of evaporator fan <br /> foreign matter. functioning and burner ignition. Heating section shall be <br /> c. Accessible service gage connections on both suction provided with the following minimum protection. <br /> and liquid lines to charge, evacuate, and measure a. Primary and auxiliary high-temperature limit switches. <br /> refrigerant pressure during any necessary servicing <br /> or troubleshooting,without losing charge. b. Induced draft motor speed sensor. <br /> d. The refrigeration system shall provide at least 15°F of c. Flame roll out switch. <br /> sub-cooling at design conditions. d. Flame proving controls. <br /> Unit Controls: e. If any of the above safety devices trip, a LED(light- <br /> emitting diode) indicator shall flash a diagnostic code <br /> a. Unit shall be complete with self-contained low-voltage that indicates which safety switch has tripped. <br /> control circuit protected by a resettable circuit breaker <br /> on the 24-volt transformer side. NOTE:All 2 Stage Gas Heat, 60%Capacity 1 st Stage, <br /> b. Unit shall incorporate a lockout circuit which provides 40%Capacity 2nd Stage. <br /> reset capability at the space thermostat or base unit, UNIT OPERATING CHARACTERISTICS <br /> should any of the following standard safety devices <br /> trip and shut off compressor. Unit shall be capable of starting and running at 125°F <br /> c. Loss-of-charge/Low-pressure switch. outdoor temperature, exceeding maximum load criteria <br /> of AHRI Standard 210/240. The compressor,with <br /> d. High-pressure switch. standard controls, shall be capable of operation down to <br /> e. Freeze-protection thermostat, evaporator coil. 0°F outdoor temperature. Unit shall be provided with fan <br /> time delay to prevent cold air delivery before heat <br /> exchanger warms up (Gas heat only). <br /> Unitary Sales Tool v1.5.9.0 Infortnation is subject to change without notice.Check local codes. Printed 03/30l2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.